TY - JOUR
T1 - Visual and refractive outcomes and complications in femtosecond laser-assisted versus conventional phacoemulsification cataract surgery
T2 - Findings from a randomised, controlled clinical trial
AU - Dzhaber, Daliya
AU - Mustafa, Osama M.
AU - Alsaleh, Fares
AU - Daoud, Yassine J.
N1 - Funding Information:
Funding Unrestricted research grants from the Michael O’Bannon Foundation and the Turner family. Wilmer Eye Institute pooled professor fund.
Publisher Copyright:
© 2020 BMJ Publishing Group. All rights reserved.
Copyright:
Copyright 2020 Elsevier B.V., All rights reserved.
PY - 2020/11/1
Y1 - 2020/11/1
N2 - Background/aim To compare visual and refractive outcomes, changes in intraocular pressure (IOP), and complications of femtosecond laser-assisted cataract surgery (FLACS) to conventional phacoemulsification surgery (CPS) in paired eyes from the same patients. Methods This is a secondary analysis of an intraindividual, randomised, controlled clinical trial including 110 paired eyes from 55 patients that were randomised into either FLACS or CPS groups. Outcomes were recorded at baseline and postoperatively during a 3-month follow-up period. Results Uncorrected distance visual acuity and corrected distance visual acuity were similar between FLACS and CPS over the follow-up period (p>0.05). The mean absolute refractive error was not significantly different between the two groups at postoperative month 1 (POM1) (0.3±0.2 D in FLACS vs 0.4±0.3 D in CPS, p=0.18) and month 3 (POM3) (0.3±0.3 D in FLACS vs 0.3±0.3 D in CPS, p=0.71). IOP was statistically higher in the FLACS group on postoperative day 1 (20.6±5.7 mm Hg for FLACS and 18.0±4.9 mm Hg for CPS, p=0.01). However, it was similar between the two groups subsequently (p>0.05). Intraoperatively, one case of posterior capsular block syndrome was observed in the FLACS group. Postoperatively, one case of newly developed glaucoma was observed in the FLACS group and one case of retinal tears in the CPS group. Conclusion The 3-month postoperative refractive and visual outcomes were comparable between FLACS and CPS in paired eyes from the same patients. Complication rate was low in the study population.
AB - Background/aim To compare visual and refractive outcomes, changes in intraocular pressure (IOP), and complications of femtosecond laser-assisted cataract surgery (FLACS) to conventional phacoemulsification surgery (CPS) in paired eyes from the same patients. Methods This is a secondary analysis of an intraindividual, randomised, controlled clinical trial including 110 paired eyes from 55 patients that were randomised into either FLACS or CPS groups. Outcomes were recorded at baseline and postoperatively during a 3-month follow-up period. Results Uncorrected distance visual acuity and corrected distance visual acuity were similar between FLACS and CPS over the follow-up period (p>0.05). The mean absolute refractive error was not significantly different between the two groups at postoperative month 1 (POM1) (0.3±0.2 D in FLACS vs 0.4±0.3 D in CPS, p=0.18) and month 3 (POM3) (0.3±0.3 D in FLACS vs 0.3±0.3 D in CPS, p=0.71). IOP was statistically higher in the FLACS group on postoperative day 1 (20.6±5.7 mm Hg for FLACS and 18.0±4.9 mm Hg for CPS, p=0.01). However, it was similar between the two groups subsequently (p>0.05). Intraoperatively, one case of posterior capsular block syndrome was observed in the FLACS group. Postoperatively, one case of newly developed glaucoma was observed in the FLACS group and one case of retinal tears in the CPS group. Conclusion The 3-month postoperative refractive and visual outcomes were comparable between FLACS and CPS in paired eyes from the same patients. Complication rate was low in the study population.
KW - clinical trial
KW - intraocular pressure
KW - lens and zonules
KW - vision
UR - http://www.scopus.com/inward/record.url?scp=85081335586&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85081335586&partnerID=8YFLogxK
U2 - 10.1136/bjophthalmol-2019-314548
DO - 10.1136/bjophthalmol-2019-314548
M3 - Article
C2 - 32066559
AN - SCOPUS:85081335586
SN - 0007-1161
VL - 104
SP - 1596
EP - 1600
JO - British Journal of Ophthalmology
JF - British Journal of Ophthalmology
IS - 11
ER -