TY - JOUR
T1 - Validation and application of a quantitative liquid chromatography tandem mass spectrometry assay for the analysis of rifapentine and 25-O-desacetyl rifapentine in human milk
AU - Mkhize, Buyisile
AU - Kellermann, Tracy
AU - Norman, Jennifer
AU - Castel, Sandra
AU - Joubert, Anton
AU - van der Merwe, Marthinus
AU - Dooley, Kelly E.
AU - Mathad, Jyoti S.
AU - Wiesner, Lubbe
N1 - Publisher Copyright:
© 2022 The Authors
PY - 2022/6/5
Y1 - 2022/6/5
N2 - A robust analytical method based on liquid chromatography coupled to tandem mass spectrometry was developed and validated to quantify rifapentine and 25-O-desacetyl rifapentine in human breast milk to aid in determining the breastfed infant risk to the excreted drug in human milk. Samples were extracted by a combination of protein precipitation and solid phase extraction using rifampicin-d3 as an internal standard. An Agilent® Poroshell 120 EC-C18 (4.6 mm × 50 mm, 2.7 µm) column was used for chromatographic separation employing an isocratic mobile phase consisting of acetonitrile: methanol: 0.1% formic acid (55/5/40, v/v/v) at a flow rate of 450 µL/min, and with a total run time of four minutes. Mass detection was on an AB Sciex API 4000 mass spectrometer using electrospray ionization in the positive mode and based on multiple reaction monitoring data acquisition. Rifapentine was accurately quantified across a concentration range of 2.00–2000 ng/mL and 25-O-desacetyl rifapentine from 4.00 to 2000 ng/mL. During validation, the inter- and intra-day accuracy and precision at the tested QC concentrations (N = 18) for rifapentine were between 97.4% and 100.6%, and 3.1% and 8.3%, respectively. The inter- and intra-day accuracy and precision for 25-O-desacetyl rifapentine were between 96.4% and 106.3%, and 6.7% and 11.8%, respectively. No significant matrix effects were observed, and the method was shown to be specific for rifapentine and 25-O-desacetyl rifapentine. Human milk samples (N = 22) generated during a phase I/II clinical trial were successfully analysed for rifapentine and 25-O-desacetyl rifapentine using this validated method. Concentrations for rifapentine and 25-O-desacetyl rifapentine in human milk samples (N = 22) ranged from 11.2-1180 ng/mL and 7.11–573 ng/mL, respectively.
AB - A robust analytical method based on liquid chromatography coupled to tandem mass spectrometry was developed and validated to quantify rifapentine and 25-O-desacetyl rifapentine in human breast milk to aid in determining the breastfed infant risk to the excreted drug in human milk. Samples were extracted by a combination of protein precipitation and solid phase extraction using rifampicin-d3 as an internal standard. An Agilent® Poroshell 120 EC-C18 (4.6 mm × 50 mm, 2.7 µm) column was used for chromatographic separation employing an isocratic mobile phase consisting of acetonitrile: methanol: 0.1% formic acid (55/5/40, v/v/v) at a flow rate of 450 µL/min, and with a total run time of four minutes. Mass detection was on an AB Sciex API 4000 mass spectrometer using electrospray ionization in the positive mode and based on multiple reaction monitoring data acquisition. Rifapentine was accurately quantified across a concentration range of 2.00–2000 ng/mL and 25-O-desacetyl rifapentine from 4.00 to 2000 ng/mL. During validation, the inter- and intra-day accuracy and precision at the tested QC concentrations (N = 18) for rifapentine were between 97.4% and 100.6%, and 3.1% and 8.3%, respectively. The inter- and intra-day accuracy and precision for 25-O-desacetyl rifapentine were between 96.4% and 106.3%, and 6.7% and 11.8%, respectively. No significant matrix effects were observed, and the method was shown to be specific for rifapentine and 25-O-desacetyl rifapentine. Human milk samples (N = 22) generated during a phase I/II clinical trial were successfully analysed for rifapentine and 25-O-desacetyl rifapentine using this validated method. Concentrations for rifapentine and 25-O-desacetyl rifapentine in human milk samples (N = 22) ranged from 11.2-1180 ng/mL and 7.11–573 ng/mL, respectively.
KW - Human milk
KW - Liquid chromatography with tandem mass spectrometry
KW - Rifapentine
KW - Tuberculosis
UR - http://www.scopus.com/inward/record.url?scp=85129556919&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85129556919&partnerID=8YFLogxK
U2 - 10.1016/j.jpba.2022.114774
DO - 10.1016/j.jpba.2022.114774
M3 - Article
C2 - 35462285
AN - SCOPUS:85129556919
SN - 0731-7085
VL - 215
JO - Journal of Pharmaceutical and Biomedical Analysis
JF - Journal of Pharmaceutical and Biomedical Analysis
M1 - 114774
ER -