Skip to main navigation Skip to search Skip to main content

Ultrafast Blood T1 Measurement Using Golden Angle Rotated Spiral k-t Sparse Parallel Imaging (GASSP): Evaluations in Both Pre- and Post-Contrast Conditions

  • Zechen Xu
  • , Feng Xu
  • , Qin Qin
  • , Dan Zhu

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: Blood T1 is a key parameter for hemodynamic quantification in both non-contrast- and contrast-enhanced imaging. Individual vessel T1 has been measured using a modified Look–Locker scheme with multi-shot EPI or FLASH in high spatial resolution, requiring ∼1 min. Here, by exploiting the temporal sparsity from the excessive number of inversion delays, we apply Golden Angle rotated Spiral k-t Sparse Parallel imaging (GASSP) to enable blood T1 measurement in a single shot of 10 s. Methods: The pulse sequence with single-shot GASSP reconstruction was developed for T1 measurement from the internal jugular vein (IJV) with 1 × 1 mm2 in-plane resolution. On nine healthy volunteers, the single-shot GASSP was compared to the segmented EPI readout and was repeated to assess its intra-scan reproducibility. Another experiment was performed on three patients, during which the 10 s GASSP was obtained at different time points prior to and following the Gadolinium (Gd) administration to assess dynamic changes in blood T1. Results: The blood T1 values measured with the highly undersampled GASSP method were strongly correlated (r = 0.83) with those using the multi-shot EPI readout and exhibited high reproducibility (r = 0.88) within the session. The baseline IJV T1 values measured were 1700–2000 ms. Following the Gd injection, the T1 values of IJVs gradually recovered from ∼300–400 to ∼500 ms within 10–15 min. Conclusion: The feasibility of an ultrafast blood T1 measurement was demonstrated with high spatial resolution in a single shot of 10 s, applicable to both pre- and post-contrast conditions.

Original languageEnglish (US)
Pages (from-to)3351-3359
Number of pages9
JournalMagnetic resonance in medicine
Volume95
Issue number6
DOIs
StatePublished - Jun 2026

Keywords

  • golden angle spiral
  • in vivo blood T
  • inversion recovery
  • k-t sparse SENSE
  • single-shot imaging

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Fingerprint