TY - JOUR
T1 - Two repetition time saturation transfer (TwiST) with spill-over correction to measure creatine kinase reaction rates in human hearts
AU - Schär, Michael
AU - Gabr, Refaat E.
AU - El-Sharkawy, Abdel Monem M.
AU - Steinberg, Angela
AU - Bottomley, Paul A.
AU - Weiss, Robert G.
N1 - Funding Information:
NIH: R01 HL56882, R01 HL61912, R01 HL63030; AHA grant #13GRNT17050100
Publisher Copyright:
© 2015 Schr et al.
PY - 2015/8/8
Y1 - 2015/8/8
N2 - Background: Phosphorus saturation transfer (ST) magnetic resonance spectroscopy can measure the rate of ATP generated from phosphocreatine (PCr) via creatine kinase (CK) in the human heart. Recently, the triple-repetition time ST (TRiST) method was introduced to measure the CK pseudo-first-order rate constant kf in three acquisitions. In TRiST, the longitudinal relaxation time of PCr while γ-ATP is saturated, T1', is measured for each subject, but suffers from low SNR because the PCr signal is reduced due to exchange with saturated γ-ATP, and the short repetition time of one of the acquisitions. Here, a two-repetition time ST (TwiST) method is presented. In TwiST, the acquisition with γ-ATP saturation and short repetition time is dropped. Instead of measuring T1', an intrinsic relaxation time T1 for PCr, T1 intrinsic, is assumed. The objective was to validate TwiST measurements of CK kinetics in healthy subjects and patients with heart failure (HF). Methods: Bloch equation simulations that included the effect of spillover irradiation on PCr were used to derive formulae for T1 intrinsic and kf measured by both TRiST and TwiST methods. Spillover was quantified from an unsaturated PCr measurement used in the current protocol for determining PCr and ATP concentrations. Cardiac TRiST and TwiST data were acquired at 3 T from 12 healthy and 17 HF patients. Results: Simulations showed that both kf measured by TwiST and T1 intrinsic require spill-over corrections. In human heart at 3 T, the spill-over corrected T1 intrinsic∈=∈8.4∈±∈1.4 s (mean∈±∈SD) independent of study group. TwiST and TRiST kf measurements were the same, but TwiST was 9 min faster. Spill-over corrected TwiST kf was 0.33∈±∈0.08 s-1 vs. 0.20∈±∈0.06 s-1 in healthy vs HF hearts, respectively (p∈<∈0.0001). Conclusion: TwiST was validated against TRiST in the human heart at 3 T, generating the same results 9 min faster. TwiST detected significant reductions in CK kf in HF compared to healthy subjects, consistent with prior 1.5 T studies using different methodology.
AB - Background: Phosphorus saturation transfer (ST) magnetic resonance spectroscopy can measure the rate of ATP generated from phosphocreatine (PCr) via creatine kinase (CK) in the human heart. Recently, the triple-repetition time ST (TRiST) method was introduced to measure the CK pseudo-first-order rate constant kf in three acquisitions. In TRiST, the longitudinal relaxation time of PCr while γ-ATP is saturated, T1', is measured for each subject, but suffers from low SNR because the PCr signal is reduced due to exchange with saturated γ-ATP, and the short repetition time of one of the acquisitions. Here, a two-repetition time ST (TwiST) method is presented. In TwiST, the acquisition with γ-ATP saturation and short repetition time is dropped. Instead of measuring T1', an intrinsic relaxation time T1 for PCr, T1 intrinsic, is assumed. The objective was to validate TwiST measurements of CK kinetics in healthy subjects and patients with heart failure (HF). Methods: Bloch equation simulations that included the effect of spillover irradiation on PCr were used to derive formulae for T1 intrinsic and kf measured by both TRiST and TwiST methods. Spillover was quantified from an unsaturated PCr measurement used in the current protocol for determining PCr and ATP concentrations. Cardiac TRiST and TwiST data were acquired at 3 T from 12 healthy and 17 HF patients. Results: Simulations showed that both kf measured by TwiST and T1 intrinsic require spill-over corrections. In human heart at 3 T, the spill-over corrected T1 intrinsic∈=∈8.4∈±∈1.4 s (mean∈±∈SD) independent of study group. TwiST and TRiST kf measurements were the same, but TwiST was 9 min faster. Spill-over corrected TwiST kf was 0.33∈±∈0.08 s-1 vs. 0.20∈±∈0.06 s-1 in healthy vs HF hearts, respectively (p∈<∈0.0001). Conclusion: TwiST was validated against TRiST in the human heart at 3 T, generating the same results 9 min faster. TwiST detected significant reductions in CK kf in HF compared to healthy subjects, consistent with prior 1.5 T studies using different methodology.
KW - 3 Tesla
KW - Creatine-kinase
KW - Heart failure
KW - High-energy phosphate
KW - Human heart
KW - Metabolism
KW - Reaction rate
KW - Saturation transfer
KW - TwiST
UR - http://www.scopus.com/inward/record.url?scp=84938679472&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84938679472&partnerID=8YFLogxK
U2 - 10.1186/s12968-015-0175-4
DO - 10.1186/s12968-015-0175-4
M3 - Article
C2 - 26253320
AN - SCOPUS:84938679472
SN - 1097-6647
VL - 17
JO - Journal of Cardiovascular Magnetic Resonance
JF - Journal of Cardiovascular Magnetic Resonance
IS - 1
M1 - 70
ER -