Skip to main navigation Skip to search Skip to main content

Treatment planning and 3D dose verification of whole brain radiation therapy with hippocampal avoidance in rats

  • S. W. Yoon
  • , D. Miles
  • , C. Cramer
  • , M. Reinsvold
  • , D. Kirsch
  • , M. Oldham

Research output: Contribution to journalConference articlepeer-review

Abstract

Despite increasing use of stereotactic radiosurgery, whole brain radiotherapy (WBRT) continues to have a therapeutic role in a selected subset of patients. Selectively avoiding the hippocampus during such treatment (HA-WBRT) emerged as a strategy to reduce the cognitive morbidity associated with WBRT and gave rise to a recently published the phase II trial (RTOG 0933) and now multiple ongoing clinical trials. While conceptually hippocampal avoidance is supported by pre-clinical evidence showing that the hippocampus plays a vital role in memory, there is minimal pre-clinic data showing that selectively avoiding the hippocampus will reduce radiation-induced cognitive decline. Largely the lack of pre-clinical evidence can be attributed to the technical hurdles associated with delivering precise conformal treatment the rat brain. In this work we develop a novel conformal HA-WBRT technique for Wistar rats, utilizing a 225kVp micro-irradiator with precise 3D-printed radiation blocks designed to spare hippocampus while delivering whole brain dose. The technique was verified on rodent-morphic Presage® 3D dosimeters created from micro-CT scans of Wistar rats with Duke Large Field-of-View Optical Scanner (DLOS) at 1mm isotropic voxel resolution. A 4-field box with parallel opposed AP-PA and two lateral opposed fields was explored with conformal hippocampal sparing aided by 3D-printed radiation blocks. The measured DVH aligned reasonably well with that calculated from SmART Plan Monte Carlo simulations with simulated blocks for 4-field HA-WBRT with both demonstrating hippocampal sparing of 20% volume receiving less than 30% the prescription dose.

Original languageEnglish (US)
Article number012004
JournalJournal of Physics: Conference Series
Volume847
Issue number1
DOIs
StatePublished - Jun 5 2017
Externally publishedYes
Event9th International Conference on 3D Radiation Dosimetry, IC3DDose 2016 - Galveston, United States
Duration: Nov 7 2016Nov 10 2016

ASJC Scopus subject areas

  • General Physics and Astronomy

Fingerprint

Dive into the research topics of 'Treatment planning and 3D dose verification of whole brain radiation therapy with hippocampal avoidance in rats'. Together they form a unique fingerprint.

Cite this