Abstract
Object. Lateral mass screws are traditionally used to fixate the subaxial cervical spine, while pedicle screws are used in the thoracic spine. Lateral mass fixation at C-7 is challenging due to thin facets, and placing pedicle screws is difficult due to the narrow pedicles. The authors describe their clinical experience with a novel technique for transfacet screw placement for fixation at C-7. Methods. A retrospective chart review was undertaken in all patients who underwent transfacet screw placement at C-7. The technique of screw insertion was the same for each patient. Polyaxial screws between 8- and 10-mm-long were used in each case and placed through the facet from a perpendicular orientation. Postoperative radiography and clinical follow-up were analyzed for aberrant screw placement or construct failure. Results. Ten patients underwent C-7 transfacet screw placement between June 2006 and March 2007. In all but 1 patient screws were placed bilaterally, and the construct lengths ranged from C-3 to T-5. One patient with a unilateral screw had a prior facet fracture that precluded bilateral screw placement. There were no intraoperative complications or screw failures in these patients. After an average of 6 months of follow-up there were no hardware failures, and all patients showed excellent alignment. Conclusions. The authors present the first clinical demonstration of a novel technique of posterior transfacet screw placement at C-7. These results provide evidence that this technique is safe to perform and adds stability to cervicothoracic fixation.
Original language | English (US) |
---|---|
Pages (from-to) | 200-206 |
Number of pages | 7 |
Journal | Journal of Neurosurgery: Spine |
Volume | 9 |
Issue number | 2 |
DOIs | |
State | Published - Aug 2008 |
Externally published | Yes |
Keywords
- Cervical fusion
- Lateral mass
- Spinal fixation
- Spine trauma
ASJC Scopus subject areas
- Surgery
- Neurology
- Clinical Neurology