TY - JOUR
T1 - Toward adaptive stereotactic robotic brachytherapy for prostate cancer
T2 - Demonstration of an adaptive workflow incorporating inverse planning and an MR stealth robot
AU - Adam Cunha, J.
AU - Hsu, I. Chow
AU - Pouliot, Jean
AU - Roach, MacK
AU - Shinohara, Katsuto
AU - Kurhanewicz, John
AU - Reed, Galen
AU - Stoianovici, Dan
N1 - Funding Information:
This work was supported in part by the UCSF Department of Radiation Oncology and in part by Nucletron.
PY - 2010/8
Y1 - 2010/8
N2 - To translate any robot into a clinical environment, it is critical that the robot can seamlessly integrate with all the technology of a modern clinic. MRBot, an MR-stealth brachytherapy delivery device, was used in a closed-bore 3T MRI and a clinical brachytherapy cone beam CT suite. Targets included ceramic dummy seeds, MR-Spectroscopy-sensitive metabolite, and a prostate phantom. Acquired DICOM images were exported to planning software to register the robot coordinates in the imager's frame, contour and verify target locations, create dose plans, and export needle and seed positions to the robot. The coordination of each system element (imaging device, brachytherapy planning system, robot control, robot) was validated with a seed delivery accuracy of within 2 mm in both a phantom and soft tissue. An adaptive workflow was demonstrated by acquiring images after needle insertion and prior to seed deposition. This allows for adjustment if the needle is in the wrong position. Inverse planning (IPSA) was used to generate a seed placement plan and coordinates for ten needles and 29 seeds were transferred to the robot. After every two needles placed, an image was acquired. The placed seeds were identified and validated prior to placing the seeds in the next two needles. The ability to robotically deliver seeds to locations determined by IPSA and the ability of the system to incorporate novel needle patterns were demonstrated. Shown here is the ability to overcome this critical step. An adaptive brachytherapy workflow is demonstrated which integrates a clinical anatomy-based seed location optimization engine and a robotic brachytherapy device. Demonstration of this workflow is a key element of a successful translation to the clinic of the MRI stealth robotic delivery system, MRBot.
AB - To translate any robot into a clinical environment, it is critical that the robot can seamlessly integrate with all the technology of a modern clinic. MRBot, an MR-stealth brachytherapy delivery device, was used in a closed-bore 3T MRI and a clinical brachytherapy cone beam CT suite. Targets included ceramic dummy seeds, MR-Spectroscopy-sensitive metabolite, and a prostate phantom. Acquired DICOM images were exported to planning software to register the robot coordinates in the imager's frame, contour and verify target locations, create dose plans, and export needle and seed positions to the robot. The coordination of each system element (imaging device, brachytherapy planning system, robot control, robot) was validated with a seed delivery accuracy of within 2 mm in both a phantom and soft tissue. An adaptive workflow was demonstrated by acquiring images after needle insertion and prior to seed deposition. This allows for adjustment if the needle is in the wrong position. Inverse planning (IPSA) was used to generate a seed placement plan and coordinates for ten needles and 29 seeds were transferred to the robot. After every two needles placed, an image was acquired. The placed seeds were identified and validated prior to placing the seeds in the next two needles. The ability to robotically deliver seeds to locations determined by IPSA and the ability of the system to incorporate novel needle patterns were demonstrated. Shown here is the ability to overcome this critical step. An adaptive brachytherapy workflow is demonstrated which integrates a clinical anatomy-based seed location optimization engine and a robotic brachytherapy device. Demonstration of this workflow is a key element of a successful translation to the clinic of the MRI stealth robotic delivery system, MRBot.
KW - Adaptive workflow
KW - Prostate cancer
KW - Robotic brachytherapy
KW - Seed location
UR - http://www.scopus.com/inward/record.url?scp=77954798125&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77954798125&partnerID=8YFLogxK
U2 - 10.3109/13645706.2010.497000
DO - 10.3109/13645706.2010.497000
M3 - Article
C2 - 20642386
AN - SCOPUS:77954798125
SN - 1364-5706
VL - 19
SP - 189
EP - 202
JO - Minimally Invasive Therapy and Allied Technologies
JF - Minimally Invasive Therapy and Allied Technologies
IS - 4
ER -