TY - JOUR
T1 - Technique for preparation of the corneal endothelium-Descemet membrane complex for transplantation
AU - Zhu, Zejin
AU - Rife, Lawrence
AU - Yiu, Samuel
AU - Trousdale, Melvin D.
AU - Wasilewski, Daniel
AU - Siqueira, Alexandre
AU - Smith, Ronald E.
N1 - Copyright:
Copyright 2008 Elsevier B.V., All rights reserved.
PY - 2006/7
Y1 - 2006/7
N2 - PURPOSE: Replacing diseased corneal endothelium with a preparation of Descemet membrane carrying functional endothelium and no stroma may be a feasible method for treating corneal endothelial decompensation. To obtain a viable donor of a Descemet membrane endothelium disc, we modified the Descemet membrane stripping technique and monitored the percentage of endothelial damage to the donor tissue preparation. METHODS: Forty-eight human corneas were used. Cornea buttons were mounted on an artificial anterior chamber, endothelial side up. Endothelia were stained with alizarin red, examined under the microscope, and photographed at 5 different sites (microscope, x100; digital magnification, x2.83). A 6 x 7-mm rectangular piece of endothelium-Descemet membrane complex was obtained using a Grieshaber microsurgical knife and Kelman-McPherson forceps. Digital photographs of endothelia were analyzed with a computer, and the percentage of endothelial damage was calculated. Specimens were processed for hematoxylin-eosin staining. RESULTS: Forty of 48 endothelium-Descemet membrane preparations (83.3%) were complete peels with minimal endothelial damage. Endothelial damage before and after the surgery was 1.57 ± 2.11% and 2.61 ± 1.77%, respectively. Eight preparations (16.7%) failed because of tearing. Multiple hematoxylin-eosin-stained sections showed the presence of endothelium with intact Descemet membrane and no stromal tissue. CONCLUSION: We modified the technique of Melles and obtained a sheet of Descemet membrane and endothelium with minimal endothelial damage and with no remaining stroma observed. This simple technique can be used to obtain the endothelium-Descemet membrane complex in minutes. It may be useful for corneal endothelium transplantation.
AB - PURPOSE: Replacing diseased corneal endothelium with a preparation of Descemet membrane carrying functional endothelium and no stroma may be a feasible method for treating corneal endothelial decompensation. To obtain a viable donor of a Descemet membrane endothelium disc, we modified the Descemet membrane stripping technique and monitored the percentage of endothelial damage to the donor tissue preparation. METHODS: Forty-eight human corneas were used. Cornea buttons were mounted on an artificial anterior chamber, endothelial side up. Endothelia were stained with alizarin red, examined under the microscope, and photographed at 5 different sites (microscope, x100; digital magnification, x2.83). A 6 x 7-mm rectangular piece of endothelium-Descemet membrane complex was obtained using a Grieshaber microsurgical knife and Kelman-McPherson forceps. Digital photographs of endothelia were analyzed with a computer, and the percentage of endothelial damage was calculated. Specimens were processed for hematoxylin-eosin staining. RESULTS: Forty of 48 endothelium-Descemet membrane preparations (83.3%) were complete peels with minimal endothelial damage. Endothelial damage before and after the surgery was 1.57 ± 2.11% and 2.61 ± 1.77%, respectively. Eight preparations (16.7%) failed because of tearing. Multiple hematoxylin-eosin-stained sections showed the presence of endothelium with intact Descemet membrane and no stromal tissue. CONCLUSION: We modified the technique of Melles and obtained a sheet of Descemet membrane and endothelium with minimal endothelial damage and with no remaining stroma observed. This simple technique can be used to obtain the endothelium-Descemet membrane complex in minutes. It may be useful for corneal endothelium transplantation.
KW - Artificial anterior chamber
KW - Cornea endothelium-Descemet membrane preparation
KW - Corneoscleral button
KW - Endothelial transplantation
UR - http://www.scopus.com/inward/record.url?scp=33750570727&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33750570727&partnerID=8YFLogxK
U2 - 10.1097/01.ico.0000214229.21238.eb
DO - 10.1097/01.ico.0000214229.21238.eb
M3 - Article
C2 - 17077665
AN - SCOPUS:33750570727
SN - 0277-3740
VL - 25
SP - 705
EP - 708
JO - Cornea
JF - Cornea
IS - 6
ER -