TY - JOUR
T1 - Steroid elution improves the stimulation threshold in an active-fixation atrial permanent pacing lead
T2 - A randomized, controlled study
AU - Crossley, George H.
AU - Brinker, Jeffrey A.
AU - Reynolds, Dwight
AU - Spencer, William
AU - Johnson, W. Ben
AU - Hurd, Howard
AU - Tonder, Lisa
AU - Zmijewski, Matt
PY - 1995/11/15
Y1 - 1995/11/15
N2 - Background: Prior work suggests that the addition of a steroid-eluting reservoir to a passive-fixation permanent pacemaker lead improves the stimulation threshold; however, no large randomized study has addressed this issue. Over the last several years, there has been an increase in enthusiasm for the use of active-fixation permanent pacemaker leads for various reasons in spite of the generally accepted notion that active-fixation leads have higher stimulation thresholds. Methods and Results: This multicenter, randomized, controlled study examined the difference in performance between a standard active-fixation atrial lead (Medtronic model 4058) and a steroid- eluting lead (Medtronic model 4068). Stimulation thresholds were obtained in a four-point strength-duration fashion. Evaluations of sensing and impedance were performed as well. These evaluations were performed at implantation, at weeks 1 through 4, and at weeks 6, 12, 24, and 52. Stimulation thresholds were significantly better in the steroid lead than in the nonsteroid lead at each measurement point from 1 week to 12 months. The mean 1.6-V stimulation threshold at 12 months was 0.19±0.2 ms in the steroid lead and 0.41±0.30 ms in the control lead. No acute peaking was observed with the steroid lead, whereas significant peaking was observed with the control lead. There was no difference in long-term sensing or impedance. Conclusions: Inclusion of a steroid-eluting reservoir in an active-fixation permanent pacing lead improved stimulation thresholds in both the subacute and chronic periods and therefore should extend pulse-generator longevity.
AB - Background: Prior work suggests that the addition of a steroid-eluting reservoir to a passive-fixation permanent pacemaker lead improves the stimulation threshold; however, no large randomized study has addressed this issue. Over the last several years, there has been an increase in enthusiasm for the use of active-fixation permanent pacemaker leads for various reasons in spite of the generally accepted notion that active-fixation leads have higher stimulation thresholds. Methods and Results: This multicenter, randomized, controlled study examined the difference in performance between a standard active-fixation atrial lead (Medtronic model 4058) and a steroid- eluting lead (Medtronic model 4068). Stimulation thresholds were obtained in a four-point strength-duration fashion. Evaluations of sensing and impedance were performed as well. These evaluations were performed at implantation, at weeks 1 through 4, and at weeks 6, 12, 24, and 52. Stimulation thresholds were significantly better in the steroid lead than in the nonsteroid lead at each measurement point from 1 week to 12 months. The mean 1.6-V stimulation threshold at 12 months was 0.19±0.2 ms in the steroid lead and 0.41±0.30 ms in the control lead. No acute peaking was observed with the steroid lead, whereas significant peaking was observed with the control lead. There was no difference in long-term sensing or impedance. Conclusions: Inclusion of a steroid-eluting reservoir in an active-fixation permanent pacing lead improved stimulation thresholds in both the subacute and chronic periods and therefore should extend pulse-generator longevity.
KW - electrical stimulation
KW - pacemakers
KW - trials
UR - http://www.scopus.com/inward/record.url?scp=0028821712&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0028821712&partnerID=8YFLogxK
U2 - 10.1161/01.CIR.92.10.2935
DO - 10.1161/01.CIR.92.10.2935
M3 - Article
C2 - 7586262
AN - SCOPUS:0028821712
SN - 0009-7322
VL - 92
SP - 2935
EP - 2939
JO - Circulation
JF - Circulation
IS - 10
ER -