Abstract
We propose a method to simulate atrophy and other similar volumetric change effects on medical images. Given a desired level of atrophy, we find a dense warping deformation that produces the corresponding levels of volumetric loss on the labeled tissue using an energy minimization strategy. Simulated results on a real brain image indicate that the method generates realistic images of tissue loss. The method does not make assumptions regarding the mechanics of tissue deformation, and provides a framework where a pre-specifled pattern of atrophy can readily be simulated. Furthermore, it provides exact correspondences between images prior and posterior to the atrophy that can be used to evaluate provisional image registration and atrophy quantification algorithms.
| Original language | English (US) |
|---|---|
| Pages (from-to) | 649-652 |
| Number of pages | 4 |
| Journal | IEEE transactions on medical imaging |
| Volume | 25 |
| Issue number | 5 |
| DOIs | |
| State | Published - May 2006 |
| Externally published | Yes |