Abstract
A method of achieving arterial control by inserting an embolectomy catheter through the femoral introducer sheath in the patient with femoral arterial bleeding after PTCA is described herein. This approach allows quick control with less dissection and negligible blood loss.
Original language | English (US) |
---|---|
Pages (from-to) | 515-516 |
Number of pages | 2 |
Journal | Surgery Gynecology and Obstetrics |
Volume | 171 |
Issue number | 6 |
State | Published - Dec 1 1990 |
ASJC Scopus subject areas
- Surgery
- Obstetrics and Gynecology