TY - JOUR
T1 - Significance of the signal-to-cutoff ratios of anti-hepatitis C virus enzyme immunoassays in screening of Chinese blood donors
AU - Ren, Fu Rong
AU - Lv, Qiu Shuang
AU - Zhuang, Hui
AU - Li, Jing Jing
AU - Gong, Xiao Yan
AU - Gao, Guo Jing
AU - Liu, Chang Li
AU - Wang, Jing Xing
AU - Yao, Fu Zhu
AU - Zheng, You Rong
AU - Zhu, Fa Ming
AU - Tiemuer, Mei Hei Li
AU - Bai, Xu Hua
AU - Shan, Hua
PY - 2005/11
Y1 - 2005/11
N2 - BACKGROUND: The correlation between signal-to-cutoff (S/CO) ratios of a second-generation hepatitis C virus (HCV) enzyme immunoassay (EIA; Abbott) and a third-generation HCV enzyme-linked immunosorbent assay (ELISA; Ortho) and confirmed HCV infection has been reported. The utility of the values for the Chinese anti-HCV EIA kits, however, has not been studied in evaluating test results in Chinese blood donors. STUDY DESIGN AND METHODS: A total of 156 donor samples repeat reactive for anti-HCV at routine screening from five representative regions of China were retested for anti-HCV by the Ortho third-generation HCV ELISA and six Chinese EIA kits and for HCV RNA by a human immunodeficiency virus-1 and HCV assay (Procleix, Chiron Corp.). The HCV RNA-nonreactive samples were further tested for anti-HCV by a third-generation recombinant immunoblot assay RIBA (Chiron Corp.). The positive result by either nucleic acid amplification test or RIBA was interpreted as confirmed HCV infection. RESULTS: The confirmed HCV prevalence rate in donors in five representative regions obtained in this study was 0.20 percent (77/37,900) in 2004. All seven anti-HCV EIA kits had a significant correlation between S/CO ratios and confirmed HCV infection. The threshold S/CO ratios, which predicted more than 95 percent of confirmed HCV infections for the Ortho, SABC, BGI-GBI, InTec, GWK, KHB, and WANTAI kits, were 3.8, 6.0, 7.0, 8.6, 10.0, 10.0, and 14.0, respectively. CONCLUSIONS: Anti-HCV EIA kits commonly used in Chinese donors screening demonstrate good correlation between S/CO ratios and the confirmed infection. For the Ortho third-generation HCV ELISA, the S/CO ratio of 3.8 determined by the US Centers for Disease Control and Prevention is applicable to Chinese blood donors. The Chinese domestic EIA kits evaluated show a diverse range of threshold S/CO ratios.
AB - BACKGROUND: The correlation between signal-to-cutoff (S/CO) ratios of a second-generation hepatitis C virus (HCV) enzyme immunoassay (EIA; Abbott) and a third-generation HCV enzyme-linked immunosorbent assay (ELISA; Ortho) and confirmed HCV infection has been reported. The utility of the values for the Chinese anti-HCV EIA kits, however, has not been studied in evaluating test results in Chinese blood donors. STUDY DESIGN AND METHODS: A total of 156 donor samples repeat reactive for anti-HCV at routine screening from five representative regions of China were retested for anti-HCV by the Ortho third-generation HCV ELISA and six Chinese EIA kits and for HCV RNA by a human immunodeficiency virus-1 and HCV assay (Procleix, Chiron Corp.). The HCV RNA-nonreactive samples were further tested for anti-HCV by a third-generation recombinant immunoblot assay RIBA (Chiron Corp.). The positive result by either nucleic acid amplification test or RIBA was interpreted as confirmed HCV infection. RESULTS: The confirmed HCV prevalence rate in donors in five representative regions obtained in this study was 0.20 percent (77/37,900) in 2004. All seven anti-HCV EIA kits had a significant correlation between S/CO ratios and confirmed HCV infection. The threshold S/CO ratios, which predicted more than 95 percent of confirmed HCV infections for the Ortho, SABC, BGI-GBI, InTec, GWK, KHB, and WANTAI kits, were 3.8, 6.0, 7.0, 8.6, 10.0, 10.0, and 14.0, respectively. CONCLUSIONS: Anti-HCV EIA kits commonly used in Chinese donors screening demonstrate good correlation between S/CO ratios and the confirmed infection. For the Ortho third-generation HCV ELISA, the S/CO ratio of 3.8 determined by the US Centers for Disease Control and Prevention is applicable to Chinese blood donors. The Chinese domestic EIA kits evaluated show a diverse range of threshold S/CO ratios.
UR - http://www.scopus.com/inward/record.url?scp=33644662991&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33644662991&partnerID=8YFLogxK
U2 - 10.1111/j.1537-2995.2005.00611.x
DO - 10.1111/j.1537-2995.2005.00611.x
M3 - Article
C2 - 16271110
AN - SCOPUS:33644662991
SN - 0041-1132
VL - 45
SP - 1816
EP - 1822
JO - Transfusion
JF - Transfusion
IS - 11
ER -