TY - JOUR
T1 - Serum procalcitonin and C-reactive protein levels as markers of bacterial infection
T2 - A systematic review and meta-analysis
AU - Simon, Liliana
AU - Gauvin, France
AU - Amre, Devendra K.
AU - Saint-Louis, Patrick
AU - Lacroix, Jacques
PY - 2004/7/15
Y1 - 2004/7/15
N2 - A meta-analysis was performed to evaluate the accuracy of determination of procalcitonin (PCT) and C-reactive protein (CRP) levels for the diagnosis of bacterial infection. The analysis included published studies that evaluated these markers for the diagnosis of bacterial infections in hospitalized patients. PCT level was more sensitive (88% [95% confidence interval {CI}, 80%-93%] vs. 75% [95% CI, 62%-84%]) and more specific (81% [95% CI, 67%-90%] vs. 67% [95% CI, 56%-77%]) than CRP level for differentiating bacterial from noninfective causes of inflammation. The Q value for PCT markers was higher (0.82 vs. 0.73). The sensitivity for differentiating bacterial from viral infections was also higher for PCT markers (92% [95% CI, 86%-95%] vs. 86% [95% CI, 65%-95%]); the specificities were comparable (73% [95% CI, 42%-91%] vs. 70% [95% CI, 19%-96%]). The Q value was higher for PCT markers (0.89 vs. 0.83). PCT markers also had a higher positive likelihood ratio and lower negative likelihood ratio than did CRP markers in both groups. On the basis of this analysis, the diagnostic accuracy of PCT markers was higher than that of CRP markers among patients hospitalized for suspected bacterial infections.
AB - A meta-analysis was performed to evaluate the accuracy of determination of procalcitonin (PCT) and C-reactive protein (CRP) levels for the diagnosis of bacterial infection. The analysis included published studies that evaluated these markers for the diagnosis of bacterial infections in hospitalized patients. PCT level was more sensitive (88% [95% confidence interval {CI}, 80%-93%] vs. 75% [95% CI, 62%-84%]) and more specific (81% [95% CI, 67%-90%] vs. 67% [95% CI, 56%-77%]) than CRP level for differentiating bacterial from noninfective causes of inflammation. The Q value for PCT markers was higher (0.82 vs. 0.73). The sensitivity for differentiating bacterial from viral infections was also higher for PCT markers (92% [95% CI, 86%-95%] vs. 86% [95% CI, 65%-95%]); the specificities were comparable (73% [95% CI, 42%-91%] vs. 70% [95% CI, 19%-96%]). The Q value was higher for PCT markers (0.89 vs. 0.83). PCT markers also had a higher positive likelihood ratio and lower negative likelihood ratio than did CRP markers in both groups. On the basis of this analysis, the diagnostic accuracy of PCT markers was higher than that of CRP markers among patients hospitalized for suspected bacterial infections.
UR - http://www.scopus.com/inward/record.url?scp=3242810355&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=3242810355&partnerID=8YFLogxK
U2 - 10.1086/421997
DO - 10.1086/421997
M3 - Review article
C2 - 15307030
AN - SCOPUS:3242810355
SN - 1058-4838
VL - 39
SP - 206
EP - 217
JO - Clinical Infectious Diseases
JF - Clinical Infectious Diseases
IS - 2
ER -