T1 - Serial measurement of tear meniscus by FD-OCT after instillation of artificial tears in patients with dry eyes
AU - Bujak, Matthew C.
AU - Yiu, Samuel
AU - Zhang, Xinbo
AU - Li, Yan
AU - Huang, David
N1 - Copyright:
Copyright 2011 Elsevier B.V., All rights reserved.
PY - 2011/7
Y1 - 2011/7
N2 - ■ BACKGROUND AND OBJECTIVE: To use Fourier-domain optical coherence tomography (FD-OCT) to study the effect of artificial tears on the tear meniscus in patients with dry eyes. ■ PATIENTS AND METHODs: The lower tear meniscus of 16 consecutive patients with dry eyes was imaged by an FD-OCT system (RTVue; Optovue, Inc., Fremont, CA). Baseline and five serial pairs of measurements were taken after the instillation of artificial tears (Optive; Allergan, Irvine, CA) at 1, 2, 5, 10, and 15 minutes. The lower meniscus height, depth, and area were measured with a computer caliper.■ RESULTS: Baseline meniscus measurements were 235.5 ± 150.0 μ m, 138.1 ± 78.7 μ m, and 0.020 ±0.022 mm2 for height, depth, and area, respectively. After instillation of artificial tears, all lower tear meniscus parameters remained significantly elevated for 5 minutes and returned to baseline by 10 minutes. ■ CONCLUSION: FD-OCT is able to quantify a dramatic initial increase in tear meniscus, followed by a decay back to baseline values after approximately 5 minutes. FD-OCT may be useful in objectively quantifying the dynamic efficacy of dry eye treatments.
AB - ■ BACKGROUND AND OBJECTIVE: To use Fourier-domain optical coherence tomography (FD-OCT) to study the effect of artificial tears on the tear meniscus in patients with dry eyes. ■ PATIENTS AND METHODs: The lower tear meniscus of 16 consecutive patients with dry eyes was imaged by an FD-OCT system (RTVue; Optovue, Inc., Fremont, CA). Baseline and five serial pairs of measurements were taken after the instillation of artificial tears (Optive; Allergan, Irvine, CA) at 1, 2, 5, 10, and 15 minutes. The lower meniscus height, depth, and area were measured with a computer caliper.■ RESULTS: Baseline meniscus measurements were 235.5 ± 150.0 μ m, 138.1 ± 78.7 μ m, and 0.020 ±0.022 mm2 for height, depth, and area, respectively. After instillation of artificial tears, all lower tear meniscus parameters remained significantly elevated for 5 minutes and returned to baseline by 10 minutes. ■ CONCLUSION: FD-OCT is able to quantify a dramatic initial increase in tear meniscus, followed by a decay back to baseline values after approximately 5 minutes. FD-OCT may be useful in objectively quantifying the dynamic efficacy of dry eye treatments.
UR - http://www.scopus.com/inward/record.url?scp=80052914018&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=80052914018&partnerID=8YFLogxK
U2 - 10.3928/15428877-20110603-02
DO - 10.3928/15428877-20110603-02
M3 - Article
C2 - 21800803
AN - SCOPUS:80052914018
SN - 1542-8877
VL - 42
SP - 308
EP - 313
JO - Ophthalmic Surgery Lasers and Imaging
JF - Ophthalmic Surgery Lasers and Imaging
IS - 4
ER -