TY - JOUR
T1 - Sensitivity and specificity of the ViroSeq human immunodeficiency virus type 1 (HIV-1) genotyping system for detection of HIV-1 drug resistance mutations by use of an ABI PRISM 3100 genetic analyzer
AU - Eshleman, Susan H.
AU - Crutcher, Gillian
AU - Petrauskene, Olga
AU - Kunstman, Kevin
AU - Cunningham, Shawn P.
AU - Trevino, Christina
AU - Davis, Cheryl
AU - Kennedy, John
AU - Fairman, Jeff
AU - Foley, Brian
AU - Kop, Jo Ann
PY - 2005/2
Y1 - 2005/2
N2 - The ViroSeq human immunodeficiency virus type 1 (HIV-1) genotyping system is an integrated system for identification of drug resistance mutations in HIV-1 protease and reverse transcriptase (RT). Reagents are included for sample preparation, reverse transcription, PCR amplification, and sequencing. Software is provided to assemble and edit sequence data and to generate a drug resistance report. We determined the sensitivity and specificity of the ViroSeq system for mutation detection using an ABI PRISM 3100 genetic analyzer with a set of clinical samples and recombinant viruses. Twenty clinical plasma samples (viral loads, 1,800 to 10,500 copies/ml) were characterized by cloning and sequencing individual viral variants. Twelve recombinant-virus samples (viral loads, approximately 2,000 to 5,000 copies/ml) were also prepared. Eleven recombinant-virus samples contained drug resistance mutations as 40% mixtures. One recombinant-virus sample contained an insertion at codon 69 in RT (100% mutant). Plasma and recombinant-virus samples were analyzed using the ViroSeq system. Each sample was analyzed on three consecutive days at each of three testing laboratories. The sensitivity of mutation detection was 99.65% for the clinical plasma samples and 99.7% for the recombinant-virus preparations. The specificity of mutation detection was 99.95% for the clinical samples and 100% for the recombinant-virus mixtures. The base calling accuracy of the 3100 instrument was 99.91%. Mutations in clinical plasma samples and recombinant-virus samples were detected with high sensitivity and specificity, including mutations present as mixtures. This report supports the use of the ViroSeq system for identification of drug resistance mutations in HIV-1 protease and RT genes.
AB - The ViroSeq human immunodeficiency virus type 1 (HIV-1) genotyping system is an integrated system for identification of drug resistance mutations in HIV-1 protease and reverse transcriptase (RT). Reagents are included for sample preparation, reverse transcription, PCR amplification, and sequencing. Software is provided to assemble and edit sequence data and to generate a drug resistance report. We determined the sensitivity and specificity of the ViroSeq system for mutation detection using an ABI PRISM 3100 genetic analyzer with a set of clinical samples and recombinant viruses. Twenty clinical plasma samples (viral loads, 1,800 to 10,500 copies/ml) were characterized by cloning and sequencing individual viral variants. Twelve recombinant-virus samples (viral loads, approximately 2,000 to 5,000 copies/ml) were also prepared. Eleven recombinant-virus samples contained drug resistance mutations as 40% mixtures. One recombinant-virus sample contained an insertion at codon 69 in RT (100% mutant). Plasma and recombinant-virus samples were analyzed using the ViroSeq system. Each sample was analyzed on three consecutive days at each of three testing laboratories. The sensitivity of mutation detection was 99.65% for the clinical plasma samples and 99.7% for the recombinant-virus preparations. The specificity of mutation detection was 99.95% for the clinical samples and 100% for the recombinant-virus mixtures. The base calling accuracy of the 3100 instrument was 99.91%. Mutations in clinical plasma samples and recombinant-virus samples were detected with high sensitivity and specificity, including mutations present as mixtures. This report supports the use of the ViroSeq system for identification of drug resistance mutations in HIV-1 protease and RT genes.
UR - http://www.scopus.com/inward/record.url?scp=20844458574&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=20844458574&partnerID=8YFLogxK
U2 - 10.1128/JCM.43.2.813-817.2005
DO - 10.1128/JCM.43.2.813-817.2005
M3 - Article
C2 - 15695685
AN - SCOPUS:20844458574
SN - 0095-1137
VL - 43
SP - 813
EP - 817
JO - Journal of clinical microbiology
JF - Journal of clinical microbiology
IS - 2
ER -