T1 - Screening for Narrow Angles in the Singapore Population
T2 - Evaluation of New Noncontact Screening Methods
AU - Lavanya, Raghavan
AU - Foster, Paul J.
AU - Sakata, Lisandro M.
AU - Friedman, David S.
AU - Kashiwagi, Kenji
AU - Wong, Tien Yin
AU - Aung, Han T.
AU - Alfred, Tamuno
AU - Gao, Hong
AU - Ee, Adrian G.
AU - Seah, Steve K.
AU - Aung, Tin
N1 - Funding Information:
Financial Disclosure(s): Dr Kashiwagi has a Japanese patent on the SPAC (Japanese patent No. 3878164). Dr Friedman has been a paid consultant to Carl Zeiss-Meditec. Dr Foster has received honoraria and travel support from Carl Zeiss Meditec. Dr Aung has received research funding and travel support from Carl Zeiss Meditec.
Funding Information:
Supported by a grant from Singhealth Foundation, Singapore. The authors' work was independent of the funders (the funding source had no involvement).
PY - 2008/10
Y1 - 2008/10
N2 - Purpose: To assess the screening effectiveness of 3 new noncontact devices, the scanning peripheral anterior chamber depth analyzer (SPAC) (Takagi, Nagano, Japan), which measures peripheral anterior chamber depth (ACD); IOLMaster (Carl Zeiss Meditec, Jena, Germany), which measures central ACD; and Visante anterior segment optical coherence tomography (AS-OCT) (Visante, Carl Zeiss Meditec, Dublin, CA), which images the angles, and to compare these instruments with gonioscopy in identifying people with narrow angles (NAs). Design: Cross-sectional, observational, community-based study. Participants: Phakic subjects aged ≥50 years without ophthalmic symptoms who were recruited from a community polyclinic in Singapore. Methods: All subjects underwent examination with SPAC, IOLMaster, and AS-OCT in the dark by a single operator. Gonioscopy was performed by an ophthalmologist masked to the instruments' findings. The area under the curve (AUC) receiver operating characteristic (ROC) was generated to assess the performance of these tests in detecting people with a NA in either eye. Main Outcome Measures: Eyes were classified as having NAs by gonioscopy if the posterior pigmented trabecular meshwork could be seen for ≤2 quadrants of the angle circumference with or without peripheral anterior synechiae. Results: A total of 2052 subjects were examined and underwent all 3 tests. The prevalence of a NA in at least 1 eye diagnosed by gonioscopy was 20.4% (422 subjects). The AUC for the SPAC using a numeric grade <5 as a cutoff was 0.83 (95% confidence interval [CI], 0.82-0.85), with a sensitivity of 90.0% (95% CI, 86.8-92.7) and a specificity of 76.6% (95% CI, 74.4-78.6). The AUC for the IOLMaster at an ACD cutoff of <2.87 mm was 0.83 (95% CI, 0.81-0.85), with a sensitivity of 87.7% (95% CI, 84.2-90.7) and a specificity of 77.7% (95% CI, 75.6-79.7). The AUC for the AS-OCT was 0.76 (95% CI, 0.74-0.78), with a sensitivity of 88.4% (95% CI, 84.9-91.3) and a specificity of 62.9% (95% CI, 60.5-65.2). Conclusions: The low specificity found with the SPAC, IOLMaster, and AS-OCT may limit the usefulness of these devices in screening for NAs. Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references.
AB - Purpose: To assess the screening effectiveness of 3 new noncontact devices, the scanning peripheral anterior chamber depth analyzer (SPAC) (Takagi, Nagano, Japan), which measures peripheral anterior chamber depth (ACD); IOLMaster (Carl Zeiss Meditec, Jena, Germany), which measures central ACD; and Visante anterior segment optical coherence tomography (AS-OCT) (Visante, Carl Zeiss Meditec, Dublin, CA), which images the angles, and to compare these instruments with gonioscopy in identifying people with narrow angles (NAs). Design: Cross-sectional, observational, community-based study. Participants: Phakic subjects aged ≥50 years without ophthalmic symptoms who were recruited from a community polyclinic in Singapore. Methods: All subjects underwent examination with SPAC, IOLMaster, and AS-OCT in the dark by a single operator. Gonioscopy was performed by an ophthalmologist masked to the instruments' findings. The area under the curve (AUC) receiver operating characteristic (ROC) was generated to assess the performance of these tests in detecting people with a NA in either eye. Main Outcome Measures: Eyes were classified as having NAs by gonioscopy if the posterior pigmented trabecular meshwork could be seen for ≤2 quadrants of the angle circumference with or without peripheral anterior synechiae. Results: A total of 2052 subjects were examined and underwent all 3 tests. The prevalence of a NA in at least 1 eye diagnosed by gonioscopy was 20.4% (422 subjects). The AUC for the SPAC using a numeric grade <5 as a cutoff was 0.83 (95% confidence interval [CI], 0.82-0.85), with a sensitivity of 90.0% (95% CI, 86.8-92.7) and a specificity of 76.6% (95% CI, 74.4-78.6). The AUC for the IOLMaster at an ACD cutoff of <2.87 mm was 0.83 (95% CI, 0.81-0.85), with a sensitivity of 87.7% (95% CI, 84.2-90.7) and a specificity of 77.7% (95% CI, 75.6-79.7). The AUC for the AS-OCT was 0.76 (95% CI, 0.74-0.78), with a sensitivity of 88.4% (95% CI, 84.9-91.3) and a specificity of 62.9% (95% CI, 60.5-65.2). Conclusions: The low specificity found with the SPAC, IOLMaster, and AS-OCT may limit the usefulness of these devices in screening for NAs. Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references.
UR - http://www.scopus.com/inward/record.url?scp=52949152877&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=52949152877&partnerID=8YFLogxK
U2 - 10.1016/j.ophtha.2008.03.015
DO - 10.1016/j.ophtha.2008.03.015
M3 - Article
C2 - 18486215
AN - SCOPUS:52949152877
SN - 0161-6420
VL - 115
SP - 1720-1727.e2
JO - Ophthalmology
JF - Ophthalmology
IS - 10
ER -