Skip to main navigation Skip to search Skip to main content

Revealing pelvic structures in the presence of metal hip prothesis via non-circular CBCT orbits

  • Tess Reynolds
  • , Yiqun Ma
  • , Tianyu Wang
  • , Kai Mei
  • , Peter B. Noël
  • , Grace J. Gang
  • , J. Webster Stayman

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

As the expansion of Cone Beam CT (CBCT) to new interventional procedures continues, the burdensome challenge of metal artifacts remains. Photon starvation and beam hardening from metallic implants and surgical tools in the f ield of view can result in the anatomy of interest being partially or fully obscured by imaging artifacts. Leveraging the flexibility of modern robotic CBCT imaging systems, implementing non-circular orbits designed for reducing metal artifacts by ensuring data-completeness during acquisition has become a reality. Here, we investigate using non-circular orbits to reduce metal artifacts arising from metallic hip prostheses when imaging pelvic anatomy. As a f irst proof-of-concept, we implement a sinusoidal and a double-circle-arc orbit on a CBCT test bench, imaging a physical pelvis phantom, with two metal hip prostheses, housing a 3D-printed iodine-filled radial line-pair target. A standard circular orbit implemented with the CBCT test bench acted as comparator. Imaging data collection and processing, geometric calibration and image reconstruction was completed using in-house developed software programs. Imaging with the standard circular orbit, image artifacts were observed in the pelvic bones and only 33 out of the possible 45 line-pairs of the radial line-pair target were partially resolvable in the reconstructed images. Comparatively, imaging with both the sinusoid and double-circle-arc orbits reduced artifacts in the surrounding anatomy and enabled all 45 line-pairs to be visibly resolved in the reconstructed images. These results indicate the potential of non-circular orbits to assist in revealing previously obstructed structures in the pelvic region in the presence of metal hip prosthesis.

Original languageEnglish (US)
Title of host publicationMedical Imaging 2023
Subtitle of host publicationImage-Guided Procedures, Robotic Interventions, and Modeling
EditorsCristian A. Linte, Jeffrey H. Siewerdsen
PublisherSPIE
ISBN (Electronic)9781510660373
DOIs
StatePublished - 2023
EventMedical Imaging 2023: Image-Guided Procedures, Robotic Interventions, and Modeling - San Diego, United States
Duration: Feb 19 2023Feb 23 2023

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume12466
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2023: Image-Guided Procedures, Robotic Interventions, and Modeling
Country/TerritoryUnited States
CitySan Diego
Period2/19/232/23/23

Keywords

  • 3D-printing
  • CBCT
  • metal artifacts
  • non-circular orbits

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Atomic and Molecular Physics, and Optics
  • Biomaterials
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Revealing pelvic structures in the presence of metal hip prothesis via non-circular CBCT orbits'. Together they form a unique fingerprint.

Cite this