Results of a near continuous glucose monitoring technology in surgical intensive care and trauma

Eden Nohra, Sara Buckman, Kelly Bochicchio, Jad Chamieh, Stacey Reese, Corinne Merrill, Douglas Schuerer, Grant V. Bochicchio

Research output: Contribution to journalArticlepeer-review

11 Scopus citations

Abstract

Introduction Near-continuous glucose monitoring is expected to increase time in range (TIR) of 80–120 mg/dL and to avoid hypoglycemia without increasing workload. We investigated a near-continuous glucose monitor in surgical critically ill and trauma patients. Methods Patients were enrolled at a surgical intensive care unit associated with a level 1 trauma center. Glucose measurements were compared to the gold standard Yellow Springs Instrument (YSI). The technology withdraws 0.13 mL of blood every 15 min from a central venous line, centrifuges the sample, and uses mid-infrared spectroscopy to measure glucose. We plotted a Clarke Error Grid, calculated Mean Absolute Relative Deviation (MARD) to analyze trend accuracy, and we present a Bland Altman plot of device versus standard glucose measurements. Results 24 patients were enrolled. One patient was withdrawn due to poor blood return from central venous line. A total of 347 glucose measurements from 23 patients were compared to the gold standard. 94.8% of the data points were in zone A of the Clarke Error Grid and 5.2% in zone B. The MARD was 8.02%. The majority of data points achieved the benchmark for accuracy. The remaining 5.2% are clinically benign. The MARD was below 10%. The Bland Altman plot shows good agreement between the device and reference glucose measurements. There were no device related adverse events. Conclusion Our data suggests that near continuous monitoring via infrared spectroscopy is safe and accurate for use in critically ill surgical and trauma patients. A large scale multi-center study is underway to confirm these findings.

Original languageEnglish (US)
Pages (from-to)1-4
Number of pages4
JournalContemporary Clinical Trials
Volume50
DOIs
StatePublished - Sep 1 2016
Externally publishedYes

Keywords

  • Accuracy
  • Blood glucose meter
  • Continuous glucose monitoring
  • Glucose control
  • Near-infrared spectroscopy
  • Surgical intensive care

ASJC Scopus subject areas

  • Pharmacology (medical)
  • General Medicine

Fingerprint

Dive into the research topics of 'Results of a near continuous glucose monitoring technology in surgical intensive care and trauma'. Together they form a unique fingerprint.

Cite this