T1 - Regularization analysis and design for prior-image-based X-ray CT reconstruction
AU - Zhang, Hao
AU - Gang, Grace J.
AU - Dang, Hao
AU - Stayman, J. Webster
N1 - Funding Information:
Manuscript received May 14, 2018; accepted June 11, 2018. Date of publication June 13, 2018; date of current version November 29, 2018. This work was supported in part by an Academic-Industry Partnership with Elekta AB (Stockholm, Sweden), NIH under Grant R21 CA219608, and in part by the AAPM Research Seed Funding Grant. (Corresponding author: J. Webster Stayman.) The authors are with the Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205 USA (e-mail: web.stayman@jhu.edu).
Publisher Copyright:
© 1982-2012 IEEE.
PY - 2018/12
Y1 - 2018/12
N2 - Prior-image-based reconstruction (PIBR) methods have demonstrated great potential for radiation dose reduction in computed tomography applications. PIBR methods take advantage of shared anatomical information between sequential scans by incorporating a patient-specific prior image into the reconstruction objective function, often as a form of regularization. However, one major challenge with PIBR methods is how to optimally determine the prior image regularization strength which balances anatomical information from the prior image with data fitting to the current measurements. Too little prior information yields limited improvements over traditional model-based iterative reconstruction, while too much prior information can force anatomical features from the prior image not supported by the measurement data, concealing true anatomical changes. In this paper, we develop quantitative measures of the bias associated with PIBR. This bias exhibits as a fractional reconstructed contrast of the difference between the prior image and current anatomy, which is quite different from traditional reconstruction biases that are typically quantified in terms of spatial resolution or artifacts. We have derived an analytical relationship between the PIBR bias and prior image regularization strength and illustrated how this relationship can be used as a predictive tool to prospectively determine prior image regularization strength to admit specific kinds of anatomical change in the reconstruction. Because bias is dependent on local statistics, we further generalized shift-variant prior image penalties that permit uniform (shift invariant) admission of anatomical changes across the imaging field of view. We validated the mathematical framework in phantom studies and compared bias predictions with estimates based on brute force exhaustive evaluation using numerous iterative reconstructions across regularization values. The experimental results demonstrate that the proposed analytical approach can predict the bias-regularization relationship accurately, allowing for prospective determination of the prior image regularization strength in PIBR. Thus, the proposed approach provides an important tool for controlling image quality of PIBR methods in a reliable, robust, and efficient fashion.
AB - Prior-image-based reconstruction (PIBR) methods have demonstrated great potential for radiation dose reduction in computed tomography applications. PIBR methods take advantage of shared anatomical information between sequential scans by incorporating a patient-specific prior image into the reconstruction objective function, often as a form of regularization. However, one major challenge with PIBR methods is how to optimally determine the prior image regularization strength which balances anatomical information from the prior image with data fitting to the current measurements. Too little prior information yields limited improvements over traditional model-based iterative reconstruction, while too much prior information can force anatomical features from the prior image not supported by the measurement data, concealing true anatomical changes. In this paper, we develop quantitative measures of the bias associated with PIBR. This bias exhibits as a fractional reconstructed contrast of the difference between the prior image and current anatomy, which is quite different from traditional reconstruction biases that are typically quantified in terms of spatial resolution or artifacts. We have derived an analytical relationship between the PIBR bias and prior image regularization strength and illustrated how this relationship can be used as a predictive tool to prospectively determine prior image regularization strength to admit specific kinds of anatomical change in the reconstruction. Because bias is dependent on local statistics, we further generalized shift-variant prior image penalties that permit uniform (shift invariant) admission of anatomical changes across the imaging field of view. We validated the mathematical framework in phantom studies and compared bias predictions with estimates based on brute force exhaustive evaluation using numerous iterative reconstructions across regularization values. The experimental results demonstrate that the proposed analytical approach can predict the bias-regularization relationship accurately, allowing for prospective determination of the prior image regularization strength in PIBR. Thus, the proposed approach provides an important tool for controlling image quality of PIBR methods in a reliable, robust, and efficient fashion.
KW - X-ray CT
KW - prior-image-based reconstruction
KW - regularization design
UR - http://www.scopus.com/inward/record.url?scp=85048566943&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85048566943&partnerID=8YFLogxK
U2 - 10.1109/TMI.2018.2847250
DO - 10.1109/TMI.2018.2847250
M3 - Article
C2 - 29994249
AN - SCOPUS:85048566943
SN - 0278-0062
VL - 37
SP - 2675
EP - 2686
JO - IEEE transactions on medical imaging
JF - IEEE transactions on medical imaging
IS - 12