Quantitative investigation of inter-crystal scatter and penetration in the GE Discovery RX PET/CT scanner using Monte Carlo simulations

Navid Zeraatkar, Mohammad R. Ay, Saeed Sarkar, Parham Geramifar, Arman Rahmim

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

As the dimensions of crystal elements in modern PET systems is getting smaller, the fraction of events undergoing inter-crystal scattering (ICS) and penetration increases. This has deteriorative impact on the spatial resolution of images. However, with the utilization of statistical image reconstruction methods in PET, compensation for ICS and penetration impacts is feasible by accurately modeling their effects in the projection space. We aim to perform such a work for the GE Discovery RX (DRX) PET/CT system. In this work, we investigated ICS and penetration in the DRX for acquiring a quantitative view of their respective contributions. We analyzed the events in the form of coincidences instead of single photons. Also as a novelty, we discriminated between the origins of the event mispositiong. For this, we applied the GATE (Geant4 Application for Tomographic Emission) Monte Carlo toolkit and used our previously validated model of DRX. Numerous points in different positions were analyzed inside the field of view (FOV) of DRX. Finally, using geometrical symmetries of the DRX and interpolation, the fraction of ICS and penetration could be determined for all possible positions inside the FOV. The results revealed that the notable variations in quantitative behavior of ICS and penetration occurred with varying radial positions; the fraction of ICS/penetration-induced mispositioned coincidences out of true coincidences ranged from 28.7% at the center to 57.8% at the edge of the transaxial FOV. This comprehensive quantification of ICS and penetration not only provides a deeper understanding of their respective contributions, but is also aimed to be utilized in refining the system matrix in the image reconstruction task to achieve resolution modeling in the scanner.

Original languageEnglish (US)
Title of host publicationIEEE Nuclear Science Symposuim and Medical Imaging Conference, NSS/MIC 2010
Pages2403-2408
Number of pages6
DOIs
StatePublished - 2010
Externally publishedYes
Event2010 IEEE Nuclear Science Symposium, Medical Imaging Conference, NSS/MIC 2010 and 17th International Workshop on Room-Temperature Semiconductor X-ray and Gamma-ray Detectors, RTSD 2010 - Knoxville, TN, United States
Duration: Oct 30 2010Nov 6 2010

Publication series

NameIEEE Nuclear Science Symposium Conference Record
ISSN (Print)1095-7863

Other

Other2010 IEEE Nuclear Science Symposium, Medical Imaging Conference, NSS/MIC 2010 and 17th International Workshop on Room-Temperature Semiconductor X-ray and Gamma-ray Detectors, RTSD 2010
Country/TerritoryUnited States
CityKnoxville, TN
Period10/30/1011/6/10

ASJC Scopus subject areas

  • Radiation
  • Nuclear and High Energy Physics
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Quantitative investigation of inter-crystal scatter and penetration in the GE Discovery RX PET/CT scanner using Monte Carlo simulations'. Together they form a unique fingerprint.

Cite this