T1 - Quantitative comparison of the force-interval relationships of the canine right and left ventricles
AU - Burkhoff, D.
AU - Yue, D. T.
AU - Franz, M. R.
AU - Hunter, W. C.
AU - Sunagawa, K.
AU - Maughan, W. L.
AU - Sagawa, K.
PY - 1984
Y1 - 1984
N2 - We quantitatively compared the extrasystolic and postextrasystolic responses of the right ventricle and left ventricle of the same heart, which have vastly different geometries, architectures, and muscle masses. We studied nine isolated, supported canine hearts whose right and left ventricles were made to contract isovolumically with balloons placed in both chambers. The ventricles were paced with the following pattern: 20 regularly timed priming stimulations, followed by a test stimulation at a variable test pulse interval, and, finally, by a second test stimulation which was always delivered 1200 msec after the first test pulse. In each heart, approximately 15 different test pulse intervals between 300 and 1200 msec were investigated. Both the maximum developed pressure and maximum rate of pressure development, expressed as a percentage of their steady state values during the priming period were used to quantify the extra- and postextrasystolic responses. For each extrasystolic and postextrasystolic test beat, the normalized response of the right ventricle was plotted vs. that of the left ventricle. The regression line and correlation coefficient between the two were determined. The average result from nine hearts gave a slope of 0.96 ± 0.05, an intercept of 4.52 ± 4.05% and a correlation coefficient of 0.995 ± 0.004. This analysis indicated that, despite the differences in right and left ventricular geometry, architecture, and mass, their force-interval behaviors were nearly identical.
AB - We quantitatively compared the extrasystolic and postextrasystolic responses of the right ventricle and left ventricle of the same heart, which have vastly different geometries, architectures, and muscle masses. We studied nine isolated, supported canine hearts whose right and left ventricles were made to contract isovolumically with balloons placed in both chambers. The ventricles were paced with the following pattern: 20 regularly timed priming stimulations, followed by a test stimulation at a variable test pulse interval, and, finally, by a second test stimulation which was always delivered 1200 msec after the first test pulse. In each heart, approximately 15 different test pulse intervals between 300 and 1200 msec were investigated. Both the maximum developed pressure and maximum rate of pressure development, expressed as a percentage of their steady state values during the priming period were used to quantify the extra- and postextrasystolic responses. For each extrasystolic and postextrasystolic test beat, the normalized response of the right ventricle was plotted vs. that of the left ventricle. The regression line and correlation coefficient between the two were determined. The average result from nine hearts gave a slope of 0.96 ± 0.05, an intercept of 4.52 ± 4.05% and a correlation coefficient of 0.995 ± 0.004. This analysis indicated that, despite the differences in right and left ventricular geometry, architecture, and mass, their force-interval behaviors were nearly identical.
UR - http://www.scopus.com/inward/record.url?scp=0021352463&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0021352463&partnerID=8YFLogxK
U2 - 10.1161/01.RES.54.4.468
DO - 10.1161/01.RES.54.4.468
M3 - Article
C2 - 6201298
AN - SCOPUS:0021352463
SN - 0009-7330
VL - 54
SP - 468
EP - 473
JO - Circulation research
JF - Circulation research
IS - 4
ER -