TY - JOUR
T1 - Quantitative and qualitative evaluation of volume of low osmolality contrast medium needed for routine helical abdominal CT
AU - Megibow, A. J.
AU - Jacob, G.
AU - Heiken, J. P.
AU - Paulson, E. K.
AU - Hopper, K. D.
AU - Sica, G.
AU - Saini, S.
AU - Birnbaum, B. A.
AU - Redvanley, R.
AU - Fishman, E. K.
PY - 2001/1/1
Y1 - 2001/1/1
N2 - OBJECTIVE. The purpose of our study was to determine the minimum optimal dose of IV contrast medium for helical CT that can preserve image quality while reducing cost. SUBJECTS AND METHODS. Four hundred sixty-three patients from six centers were enrolled in a prospective trial in which patients were randomized into one of four weight-based dose categories of iopromide, 300 mg 1/mL: 1.25, 1.50, 1.75, and 2.0 mL/kg. Six of 463 patients were excluded from analysis. A radiologist at each center who was unaware of the volume of contrast medium administered determined whether the scans were acceptable. The responses were analyzed by dose, in aggregate, and by weight. Enhancement values (in Hounsfield units) in regions of interest in the liver, pancreas, aorta, and kidneys were obtained at a single time during the scan. The participating radiologist was unaware of these values. Finally, three additional nonparticipating site observers assessed the images for acceptability, diagnostic quality, and overall level of confidence. A cost model comparing incurred charges in using 150 or 100 mL, or 1.5 mL/kg, of low osmolality contrast medium was developed from experience in an additional 303 patients. RESULTS. We found no clinically significant difference in acceptability of scans at doses greater than 1.5 mL/kg. However, significant variability occurred among the centers. The use of 1.5 mL/kg led to a savings of $9927.16 for 303 patients when compared with the use of 150 mL at list price. The cost is the same for 1.5 mL/kg or use of 100 mL of contrast medium. CONCLUSION. A weight-based dose at 1.5 mL/kg of low osmolality contrast medium can provide acceptable scans in most patients, with a significant cost savings.
AB - OBJECTIVE. The purpose of our study was to determine the minimum optimal dose of IV contrast medium for helical CT that can preserve image quality while reducing cost. SUBJECTS AND METHODS. Four hundred sixty-three patients from six centers were enrolled in a prospective trial in which patients were randomized into one of four weight-based dose categories of iopromide, 300 mg 1/mL: 1.25, 1.50, 1.75, and 2.0 mL/kg. Six of 463 patients were excluded from analysis. A radiologist at each center who was unaware of the volume of contrast medium administered determined whether the scans were acceptable. The responses were analyzed by dose, in aggregate, and by weight. Enhancement values (in Hounsfield units) in regions of interest in the liver, pancreas, aorta, and kidneys were obtained at a single time during the scan. The participating radiologist was unaware of these values. Finally, three additional nonparticipating site observers assessed the images for acceptability, diagnostic quality, and overall level of confidence. A cost model comparing incurred charges in using 150 or 100 mL, or 1.5 mL/kg, of low osmolality contrast medium was developed from experience in an additional 303 patients. RESULTS. We found no clinically significant difference in acceptability of scans at doses greater than 1.5 mL/kg. However, significant variability occurred among the centers. The use of 1.5 mL/kg led to a savings of $9927.16 for 303 patients when compared with the use of 150 mL at list price. The cost is the same for 1.5 mL/kg or use of 100 mL of contrast medium. CONCLUSION. A weight-based dose at 1.5 mL/kg of low osmolality contrast medium can provide acceptable scans in most patients, with a significant cost savings.
UR - http://www.scopus.com/inward/record.url?scp=0035118450&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0035118450&partnerID=8YFLogxK
U2 - 10.2214/ajr.176.3.1760583
DO - 10.2214/ajr.176.3.1760583
M3 - Review article
C2 - 11222185
AN - SCOPUS:0035118450
SN - 0361-803X
VL - 176
SP - 583
EP - 589
JO - The American journal of roentgenology and radium therapy
JF - The American journal of roentgenology and radium therapy
IS - 3
ER -