TY - JOUR
T1 - Pulsed magnetization transfer imaging with body coil transmission at 3 Tesla
T2 - Feasibility and application
AU - Smith, Seth A.
AU - Farrell, Jonathan A.D.
AU - Jones, Craig K.
AU - Reich, Daniel S.
AU - Calabresi, Peter A.
AU - Van Zijl, Peter C.M.
PY - 2006/10
Y1 - 2006/10
N2 - Pulsed magnetization transfer (MT) imaging has been applied to quantitatively assess brain pathology in several diseases, especially multiple sclerosis (MS). To date, however, because of the high power deposition associated with the use of short, rapidly repeating MT prepulses, clinical application has been limited to lower field strengths. The contrast-to-noise ratio (CNR) of MT is limited, and this method would greatly benefit from the use of higher magnetic fields and phased-array coil reception. However, power deposition is proportional to the square of the magnetic field and scales with coil size, and MT experiments are already close to the SAR limit at 1.5T even when smaller transmit coils are used instead of the body coil. Here we show that these seemingly great obstacles can be ameliorated by the increased T 1 of tissue water at higher field, which allows for longer maintenance of sufficiently high saturation levels while using a reduced duty cycle. This enables a fast (5-6 min) high-resolution (1.5 mm isotropic) whole-brain MT acquisition with excellent anatomical visualization of gray matter (GM) and white matter (WM) structures, and even substructures. The method is demonstrated in nine normal volunteers and five patients with relapsing remitting MS (RRMS), and the results show a clear delineation of heterogeneous lesions.
AB - Pulsed magnetization transfer (MT) imaging has been applied to quantitatively assess brain pathology in several diseases, especially multiple sclerosis (MS). To date, however, because of the high power deposition associated with the use of short, rapidly repeating MT prepulses, clinical application has been limited to lower field strengths. The contrast-to-noise ratio (CNR) of MT is limited, and this method would greatly benefit from the use of higher magnetic fields and phased-array coil reception. However, power deposition is proportional to the square of the magnetic field and scales with coil size, and MT experiments are already close to the SAR limit at 1.5T even when smaller transmit coils are used instead of the body coil. Here we show that these seemingly great obstacles can be ameliorated by the increased T 1 of tissue water at higher field, which allows for longer maintenance of sufficiently high saturation levels while using a reduced duty cycle. This enables a fast (5-6 min) high-resolution (1.5 mm isotropic) whole-brain MT acquisition with excellent anatomical visualization of gray matter (GM) and white matter (WM) structures, and even substructures. The method is demonstrated in nine normal volunteers and five patients with relapsing remitting MS (RRMS), and the results show a clear delineation of heterogeneous lesions.
KW - 3T
KW - High field
KW - MRI
KW - Magnetization transfer
KW - Magnetization transfer ratio
KW - Multiple sclerosis
UR - http://www.scopus.com/inward/record.url?scp=33749175840&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33749175840&partnerID=8YFLogxK
U2 - 10.1002/mrm.21035
DO - 10.1002/mrm.21035
M3 - Article
C2 - 16964602
AN - SCOPUS:33749175840
SN - 0740-3194
VL - 56
SP - 866
EP - 875
JO - Magnetic resonance in medicine
JF - Magnetic resonance in medicine
IS - 4
ER -