TY - JOUR
T1 - Precision and error of three-dimensional phenotypic measures acquired from 3dMD photogrammetric images
AU - Aldridge, Kristina
AU - Boyadjiev, Simeon A.
AU - Capone, George T.
AU - DeLeon, Valerie B.
AU - Richtsmeier, Joan T.
PY - 2005/10/15
Y1 - 2005/10/15
N2 - The genetic basis for complex phenotypes is currently of great interest for both clinical investigators and basic scientists. In order to acquire a thorough understanding of the translation from genotype to phenotype, highly precise measures of phenotypic variation are required. New technologies, such as 3D photogrammetry are being implemented in phenotypic studies due to their ability to collect data rapidly and non-invasively. Before these systems can be broadly implemented, the error associated with data collected from images acquired using these technologies must be assessed. This study investigates the precision, error, and repeatability associated with anthropometric landmark coordinate data collected from 3D digital photogrammetric images acquired with the 3dMDface System. Precision, error due to the imaging system, error due to digitization of the images, and repeatability are assessed in a sample of children and adults (n = 15). Results show that data collected from images with the 3dMDface System are highly repeatable and precise. The average error associated with the placement of landmarks is sub-millimeter; both the error due to digitization and due to the imaging system are very low. The few measures showing a higher degree of error include those crossing the labial fissure, which are influenced by even subtle movement of the mandible. These results suggest that 3D anthropometric data collected using the 3dMDface System are highly reliable and, therefore, useful for evaluation of clinical dysmorphology and surgery, analyses of genotype-phenotype correlations, and inheritance of complex phenotypes.
AB - The genetic basis for complex phenotypes is currently of great interest for both clinical investigators and basic scientists. In order to acquire a thorough understanding of the translation from genotype to phenotype, highly precise measures of phenotypic variation are required. New technologies, such as 3D photogrammetry are being implemented in phenotypic studies due to their ability to collect data rapidly and non-invasively. Before these systems can be broadly implemented, the error associated with data collected from images acquired using these technologies must be assessed. This study investigates the precision, error, and repeatability associated with anthropometric landmark coordinate data collected from 3D digital photogrammetric images acquired with the 3dMDface System. Precision, error due to the imaging system, error due to digitization of the images, and repeatability are assessed in a sample of children and adults (n = 15). Results show that data collected from images with the 3dMDface System are highly repeatable and precise. The average error associated with the placement of landmarks is sub-millimeter; both the error due to digitization and due to the imaging system are very low. The few measures showing a higher degree of error include those crossing the labial fissure, which are influenced by even subtle movement of the mandible. These results suggest that 3D anthropometric data collected using the 3dMDface System are highly reliable and, therefore, useful for evaluation of clinical dysmorphology and surgery, analyses of genotype-phenotype correlations, and inheritance of complex phenotypes.
KW - Anthropometry
KW - Error
KW - Landmarks
KW - Phenotype
KW - Photogrammetry
KW - Precision
UR - http://www.scopus.com/inward/record.url?scp=25644454468&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=25644454468&partnerID=8YFLogxK
U2 - 10.1002/ajmg.a.30959
DO - 10.1002/ajmg.a.30959
M3 - Article
C2 - 16158436
AN - SCOPUS:25644454468
SN - 1552-4825
VL - 138 A
SP - 247
EP - 253
JO - American Journal of Medical Genetics
JF - American Journal of Medical Genetics
IS - 3
ER -