N2 - Thin-section multi-detector row computed tomographic (CT) colonography is a powerful tool for the detection and classification of colonic lesions. However, each step in the process of a CT colonographic examination carries the potential for misdiagnosis. Suboptimal patient preparation, CT scanning protocol deficiencies, and perception and interpretation errors can lead to false-positive and false-negative findings, adversely affecting the diagnostic performance of CT colonography. These problems and pitfalls can be overcome with a variety of useful techniques and observations. A relatively clean, dry, and welldistended colon can be achieved with careful patient preparation, thereby avoiding the problem of residual stool and fluid. Knowledge of the morphologic and attenuation characteristics of common colonic lesions and artifacts can help identify bulbous haustral folds, impacted diverticula, an inverted appendiceal stump, or mobile polyps, any of which may pose problems for the radiologist. A combined two-dimensional and three-dimensional imaging approach is recommended for each colonic finding. A thorough knowledge of the various pitfalls and pseudolesions that may be encountered at CT colonography, along with use of dedicated problem-solving techniques, will help the radiologist differentiate between definite colonic lesions and pseudolesions.
AB - Thin-section multi-detector row computed tomographic (CT) colonography is a powerful tool for the detection and classification of colonic lesions. However, each step in the process of a CT colonographic examination carries the potential for misdiagnosis. Suboptimal patient preparation, CT scanning protocol deficiencies, and perception and interpretation errors can lead to false-positive and false-negative findings, adversely affecting the diagnostic performance of CT colonography. These problems and pitfalls can be overcome with a variety of useful techniques and observations. A relatively clean, dry, and welldistended colon can be achieved with careful patient preparation, thereby avoiding the problem of residual stool and fluid. Knowledge of the morphologic and attenuation characteristics of common colonic lesions and artifacts can help identify bulbous haustral folds, impacted diverticula, an inverted appendiceal stump, or mobile polyps, any of which may pose problems for the radiologist. A combined two-dimensional and three-dimensional imaging approach is recommended for each colonic finding. A thorough knowledge of the various pitfalls and pseudolesions that may be encountered at CT colonography, along with use of dedicated problem-solving techniques, will help the radiologist differentiate between definite colonic lesions and pseudolesions.
UR - http://www.scopus.com/inward/record.url?scp=34247259402&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=34247259402&partnerID=8YFLogxK
U2 - 10.1148/rg.272065081
DO - 10.1148/rg.272065081
M3 - Review article
C2 - 17374862
AN - SCOPUS:34247259402
SN - 0271-5333
VL - 27
SP - 431
EP - 454
JO - Radiographics
JF - Radiographics
IS - 2
ER -