TY - GEN
T1 - Performance evaluation of block-iterative algorithms for SPECT reconstruction
AU - Liu, Chi
AU - Volokh, Lana
AU - Zhao, Xide
AU - Xu, Jingyan
AU - Lee, Taek Soo
AU - Tsui, Benjamin M.W.
PY - 2005/12/1
Y1 - 2005/12/1
N2 - The purpose of this study is to evaluate the performance of four block-iterative algorithms, ordered-subsets expectation-maximization (OS-EM), reseated block-iterative EM (RBI-EM), modified row-action maximum likelihood algorithm (RAMLA) and reseated block-iterative maximum a posteriori EM (RBI-MAP-EM), for In-111 ProstaScint® SPECT image reconstruction. The 3D NCAT phantom with realistic In-111 ProstaScint® activity distribution was used in the study. Noise-free and noisy projections of the phantom obtained using a medium-energy general-purpose (MEGP) collimator were generated using Monte Carlo simulation methods. For each algorithm, the projection data were reconstructed with the compensations for attenuation, collimator-detector response and scatter. Image quality was evaluated in terms of FWHM of a profile through a small blood vessel, normalized mean square error (NMSE), ensemble normalized standard deviation (NSDE) of a uniform region of interest (ROI) in the reconstructed image measured from 30 noise realizations, and regional NSD (NSDR) of an ROI measure from 1 noise realization. The results indicated that, RBI-EM has superior performance than that of OS-EM when less than 4 views per subset were used and similar performance when 4 or more views per subset were used. Modified RAMLA provides similar image quality with a slower convergence rate than that of OS-EM. Using well-chosen parameters, RBI-MAP-EM provides increased noise smoothing with less loss in resolution and error. We conclude that when compared with OS-EM, the RBI-EM and modified RAMLA have the same performance at a slower convergence rate, while the RBI-MAP-EM has superior performance and can potentially improve image quality.
AB - The purpose of this study is to evaluate the performance of four block-iterative algorithms, ordered-subsets expectation-maximization (OS-EM), reseated block-iterative EM (RBI-EM), modified row-action maximum likelihood algorithm (RAMLA) and reseated block-iterative maximum a posteriori EM (RBI-MAP-EM), for In-111 ProstaScint® SPECT image reconstruction. The 3D NCAT phantom with realistic In-111 ProstaScint® activity distribution was used in the study. Noise-free and noisy projections of the phantom obtained using a medium-energy general-purpose (MEGP) collimator were generated using Monte Carlo simulation methods. For each algorithm, the projection data were reconstructed with the compensations for attenuation, collimator-detector response and scatter. Image quality was evaluated in terms of FWHM of a profile through a small blood vessel, normalized mean square error (NMSE), ensemble normalized standard deviation (NSDE) of a uniform region of interest (ROI) in the reconstructed image measured from 30 noise realizations, and regional NSD (NSDR) of an ROI measure from 1 noise realization. The results indicated that, RBI-EM has superior performance than that of OS-EM when less than 4 views per subset were used and similar performance when 4 or more views per subset were used. Modified RAMLA provides similar image quality with a slower convergence rate than that of OS-EM. Using well-chosen parameters, RBI-MAP-EM provides increased noise smoothing with less loss in resolution and error. We conclude that when compared with OS-EM, the RBI-EM and modified RAMLA have the same performance at a slower convergence rate, while the RBI-MAP-EM has superior performance and can potentially improve image quality.
UR - http://www.scopus.com/inward/record.url?scp=33846624380&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33846624380&partnerID=8YFLogxK
U2 - 10.1109/NSSMIC.2005.1596676
DO - 10.1109/NSSMIC.2005.1596676
M3 - Conference contribution
AN - SCOPUS:33846624380
SN - 0780392213
SN - 9780780392212
T3 - IEEE Nuclear Science Symposium Conference Record
SP - 1827
EP - 1831
BT - 2005 IEEE Nuclear Science Symposium Conference Record -Nuclear Science Symposium and Medical Imaging Conference
T2 - Nuclear Science Symposium Conference Record, 2005 IEEE
Y2 - 23 October 2005 through 29 October 2005
ER -