Skip to main navigation Skip to search Skip to main content

Patellofemoral joint: Identification of abnormalities with active- movement, 'unloaded' versus 'loaded' kinematic MR imaging techniques

  • F. G. Shellock
  • , J. H. Mink
  • , A. L. Deutsch
  • , T. K. Foo
  • , P. Sullenberger

Research output: Contribution to journalArticlepeer-review

Abstract

A positioning device was used to apply a 'load' to stress the patellofemoral joint during active-movement, kinematic magnetic resonance (MR) imaging. Twenty-three symptomatic patellofemoral joints were studied by using 'unloaded' versus 'loaded' techniques. With the unloaded technique, seven joints were normal, nine had lateral subluxation, three had lateral tilt, and four had medial subluxation. With the loaded technique, one was normal, 13 had lateral subluxation, four had lateral tilt, and five had medial subluxation. The active-movement, loaded kinematic MR imaging technique provides improved ability to identify patellofemoral joint abnormalities.

Original languageEnglish (US)
Pages (from-to)575-578
Number of pages4
JournalRadiology
Volume188
Issue number2
StatePublished - 1993
Externally publishedYes

Keywords

  • Joints, abnormalities
  • Knee, abnormalities
  • Knee, MR
  • Patella

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology

Fingerprint

Dive into the research topics of 'Patellofemoral joint: Identification of abnormalities with active- movement, 'unloaded' versus 'loaded' kinematic MR imaging techniques'. Together they form a unique fingerprint.