TY - JOUR
T1 - Outcomes after heart transplantation in sensitized patients bridged with ventricular assist devices
AU - Fraser, Charles D.
AU - Zhou, Xun
AU - Magruder, J. Trent
AU - Suarez-Pierre, Alejandro
AU - Lui, Cecillia
AU - Grimm, Joshua C.
AU - Higgins, Robert
AU - Kilic, Ahmet
PY - 2019/6/1
Y1 - 2019/6/1
N2 - Objective: Sensitization has been associated with worse outcomes following heart transplantation (HTx). The use of ventricular assist devices (VAD) is a risk factor for the development of sensitization. We investigated the impact of left ventricular assist devices (LVAD) and sensitization in HTx recipients. Methods: We queried the UNOS database for all heart transplants performed from January 2000 through December 2016. Patients were considered highly sensitized and included if panel-reactive antibody (PRA) activity was 25% or higher. Patients were separated by pretransplant LVAD utilization and subgroup analysis was performed by device type (HeartMate II or HeartWare). Outcomes included Kaplan-Meier survival and episodes of rejection within 1 year of HTx. Results: Of 18 009 recipients, 2434 (14%) were highly sensitized. 1055 (43.3%) were bridged with a VAD. In multivariate analysis, LVAD use did not impact 1-year (hazards ratio [HR], 1.30; P = 0.052) or 5-year survival (HR, 1.18; P = 0.112) in highly sensitized recipients. Furthermore, episodes of rejection were not affected by LVAD status (P = 0.765). Of the 1055 sensitized LVAD-bridged transplant recipients, 624 (59%) were implanted with a HeartMate II and 99 (9.4%) were bridged with a HeartWare device. In multivariate analysis, no differences were observed in 1-year survival (HR, 0.86; P = 0.664), 5-year survival (HR, 1.35; P = 0.209), or episodes of rejection (P = 0.497). Conclusions: The use of ventricular assist devices did not impact survival or rejection within 1 year of HTx in highly sensitized patients. Highly sensitized recipients have similar outcomes regardless of prior LVAD support or type of LVAD used as a bridge to transplantation.
AB - Objective: Sensitization has been associated with worse outcomes following heart transplantation (HTx). The use of ventricular assist devices (VAD) is a risk factor for the development of sensitization. We investigated the impact of left ventricular assist devices (LVAD) and sensitization in HTx recipients. Methods: We queried the UNOS database for all heart transplants performed from January 2000 through December 2016. Patients were considered highly sensitized and included if panel-reactive antibody (PRA) activity was 25% or higher. Patients were separated by pretransplant LVAD utilization and subgroup analysis was performed by device type (HeartMate II or HeartWare). Outcomes included Kaplan-Meier survival and episodes of rejection within 1 year of HTx. Results: Of 18 009 recipients, 2434 (14%) were highly sensitized. 1055 (43.3%) were bridged with a VAD. In multivariate analysis, LVAD use did not impact 1-year (hazards ratio [HR], 1.30; P = 0.052) or 5-year survival (HR, 1.18; P = 0.112) in highly sensitized recipients. Furthermore, episodes of rejection were not affected by LVAD status (P = 0.765). Of the 1055 sensitized LVAD-bridged transplant recipients, 624 (59%) were implanted with a HeartMate II and 99 (9.4%) were bridged with a HeartWare device. In multivariate analysis, no differences were observed in 1-year survival (HR, 0.86; P = 0.664), 5-year survival (HR, 1.35; P = 0.209), or episodes of rejection (P = 0.497). Conclusions: The use of ventricular assist devices did not impact survival or rejection within 1 year of HTx in highly sensitized patients. Highly sensitized recipients have similar outcomes regardless of prior LVAD support or type of LVAD used as a bridge to transplantation.
KW - heart transplantation
KW - panel-reactive antibody
KW - sensitization
UR - http://www.scopus.com/inward/record.url?scp=85066864013&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85066864013&partnerID=8YFLogxK
U2 - 10.1111/jocs.14066
DO - 10.1111/jocs.14066
M3 - Article
C2 - 31045281
AN - SCOPUS:85066864013
SN - 0886-0440
VL - 34
SP - 474
EP - 481
JO - Journal of Cardiac Surgery
JF - Journal of Cardiac Surgery
IS - 6