Skip to main navigation Skip to search Skip to main content

Optimizing energy threshold selection for low-concentration contrast agent quantification in small animal photon-counting CT

Research output: Contribution to journalArticlepeer-review

Abstract

Objective. Gold nanoparticles (GNPs) are widely used for biological research and applications. The in-vivo concentration of GNPs is usually low due to biological safety concerns, thus posing a challenge for imaging. This work investigates on optimal energy threshold selection in photon-counting detector(PCD)-based CT (PCCT) for the quantification of low-concentration GNPs. Approach. We derived the mathematical expression of the upper bound of the material decomposition error in the gold image. Comprehensive simulations were implemented for cylindrical phantom with inserts of different GNP concentrations. CT scans of this phantom were simulated with a 140 kVp x-ray beam under a realistic pre-clinical CT dose range. The PCD energy thresholds from 30 to 110 keV were enumerated for 2,3-channel PCCT and the optimal energy thresholds were determined by searching for the lowest decomposition error. Main results. The optimal energy threshold(s) to minimize the decomposition error in gold image was 44 keV for the 2-channel PCCT and { 34 , 40 } keV for the 3-channel case. Numerical results also validated the derived upper bounds of the decomposition error. Significance. This work addressed the need for selecting appropriate energy thresholds for accurate quantification of contrast agent distributions in pre-clinical PCCT. Both the analytical expression of the upper bound of material decomposition error and simulation results showed that the balanced consideration on photon counting noise levels and the numerical properties of the decomposition matrix is required in selecting the appropriate energy thresholds to achieve the most accurate material decomposition.

Original languageEnglish (US)
Article number045004
JournalPhysics in medicine and biology
Volume70
Issue number4
DOIs
StatePublished - Feb 16 2025

Keywords

  • gold nanoparticle quantification
  • material decomposition
  • photon-counting detector

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Optimizing energy threshold selection for low-concentration contrast agent quantification in small animal photon-counting CT'. Together they form a unique fingerprint.

Cite this