T1 - Occult right ventricular dysfunction and right ventricular-vascular uncoupling in left ventricular assist device recipients
AU - Scheel, Paul J.
AU - Cubero Salazar, Ilton M.
AU - Friedman, Samuel
AU - Haber, Leora
AU - Mukherjee, Monica
AU - Kauffman, Matthew
AU - Weller, Alexandra
AU - Alkhunaizi, Fatimah
AU - Gilotra, Nisha A.
AU - Sharma, Kavita
AU - Kilic, Ahmet
AU - Hassoun, Paul M.
AU - Cornwell, William K.
AU - Tedford, Ryan J.
AU - Hsu, Steven
N1 - Publisher Copyright:
© 2023 The Authors
PY - 2024/4
Y1 - 2024/4
N2 - Background: Detecting right heart failure post left ventricular assist device (LVAD) is challenging. Sensitive pressure-volume loop assessments of right ventricle (RV) contractility may improve our appreciation of post-LVAD RV dysfunction. Methods: Thirteen LVAD patients and 20 reference (non-LVAD) subjects underwent comparison of echocardiographic, right heart cath hemodynamic, and pressure-volume loop-derived assessments of RV contractility using end-systolic elastance (Ees), RV afterload by effective arterial elastance (Ea), and RV-pulmonary arterial coupling (ratio of Ees/Ea). Results: LVAD patients had lower RV Ees (0.20 ± 0.08 vs 0.30 ± 0.15 mm Hg/ml, p = 0.01) and lower RV Ees/Ea (0.37 ± 0.14 vs 1.20 ± 0.54, p < 0.001) versus reference subjects. Low RV Ees correlated with reduced RV septal strain, an indicator of septal contractility, in both the entire cohort (r = 0.68, p = 0.004) as well as the LVAD cohort itself (r = 0.78, p = 0.02). LVAD recipients with low RV Ees/Ea (below the median value) demonstrated more clinical heart failure (71% vs 17%, p = 0.048), driven by an inability to augment RV Ees (0.22 ± 0.11 vs 0.19 ± 0.02 mm Hg/ml, p = 0.95) to accommodate higher RV Ea (0.82 ± 0.38 vs 0.39 ± 0.08 mm Hg/ml, p = 0.002). Pulmonary artery pulsatility index (PAPi) best identified low baseline RV Ees/Ea (≤0.35) in LVAD patients ((area under the curve) AUC = 0.80); during the ramp study, change in PAPi also correlated with change in RV Ees/Ea (r = 0.58, p = 0.04). Conclusions: LVAD patients demonstrate occult intrinsic RV dysfunction. In the setting of excess RV afterload, LVAD patients lack the RV contractile reserve to maintain ventriculo-vascular coupling. Depression in RV contractility may be related to LVAD left ventricular unloading, which reduces septal contractility.
AB - Background: Detecting right heart failure post left ventricular assist device (LVAD) is challenging. Sensitive pressure-volume loop assessments of right ventricle (RV) contractility may improve our appreciation of post-LVAD RV dysfunction. Methods: Thirteen LVAD patients and 20 reference (non-LVAD) subjects underwent comparison of echocardiographic, right heart cath hemodynamic, and pressure-volume loop-derived assessments of RV contractility using end-systolic elastance (Ees), RV afterload by effective arterial elastance (Ea), and RV-pulmonary arterial coupling (ratio of Ees/Ea). Results: LVAD patients had lower RV Ees (0.20 ± 0.08 vs 0.30 ± 0.15 mm Hg/ml, p = 0.01) and lower RV Ees/Ea (0.37 ± 0.14 vs 1.20 ± 0.54, p < 0.001) versus reference subjects. Low RV Ees correlated with reduced RV septal strain, an indicator of septal contractility, in both the entire cohort (r = 0.68, p = 0.004) as well as the LVAD cohort itself (r = 0.78, p = 0.02). LVAD recipients with low RV Ees/Ea (below the median value) demonstrated more clinical heart failure (71% vs 17%, p = 0.048), driven by an inability to augment RV Ees (0.22 ± 0.11 vs 0.19 ± 0.02 mm Hg/ml, p = 0.95) to accommodate higher RV Ea (0.82 ± 0.38 vs 0.39 ± 0.08 mm Hg/ml, p = 0.002). Pulmonary artery pulsatility index (PAPi) best identified low baseline RV Ees/Ea (≤0.35) in LVAD patients ((area under the curve) AUC = 0.80); during the ramp study, change in PAPi also correlated with change in RV Ees/Ea (r = 0.58, p = 0.04). Conclusions: LVAD patients demonstrate occult intrinsic RV dysfunction. In the setting of excess RV afterload, LVAD patients lack the RV contractile reserve to maintain ventriculo-vascular coupling. Depression in RV contractility may be related to LVAD left ventricular unloading, which reduces septal contractility.
KW - echocardiographic strain
KW - left ventricular assist device
KW - pressure-volume loop
KW - pulmonary hypertension
KW - right heart failure
UR - http://www.scopus.com/inward/record.url?scp=85179823669&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85179823669&partnerID=8YFLogxK
U2 - 10.1016/j.healun.2023.11.015
DO - 10.1016/j.healun.2023.11.015
M3 - Article
C2 - 38036276
AN - SCOPUS:85179823669
SN - 1053-2498
VL - 43
SP - 594
EP - 603
JO - Journal of Heart and Lung Transplantation
JF - Journal of Heart and Lung Transplantation
IS - 4
ER -