N2 - Background Release of tethered spinal cord by sectioning of the filum terminale carries a significant risk of injury to the neighboring motor and sensory nerve roots. Intraoperative neurophysiological monitoring techniques can help to minimize these adverse neurologic outcomes. Methods We performed a retrospective review of 67 consecutive patients undergoing tethered cord release. We excluded 52 pediatric patients which limited our study to 15 adult patients treated during a four year period, including patients with a thick filum, low lying conus, myelomeningocele, filum tumor, spinal cord malformation, and/or lipoma. Clinical outcomes were determined from postoperative follow-up visits. Two patients were lost to follow up and were excluded from the clinical outcome analysis. Electrical stimulation of the filum terminale and lumbo-sacral nerve roots in conjunction with electromyogram (EMG) recording was performed intraoperatively. Results The mean electrical threshold for EMG response during stimulation of the filum terminale was 37.1 volts (V), range 15 to 100 V. In comparison, the lowest threshold obtained by direct stimulation of the ventral nerve roots was a mean of 1.46 V, with a range of 0.1 to 7 V. More than 70% of the patients studied demonstrated a filum to motor root threshold ratio of 100:1 or greater. No patient developed new neurologic symptoms or signs postoperatively. Bowel and bladder function improved in 46% of patients, back pain in 39% and motor function in 31%. Eight percent reported decline in bladder control and worsening back pain postoperatively. Conclusions The often dramatic difference in the threshold of the filum terminale and adjacent motor nerve roots (100:1) helps to identify, isolate, and safely section the filum terminale. Tethered cord release using intraoperative neurophysiological monitoring is safe and in the majority of cases leads to improvement or at least, stabilization of neurologic function. Monitoring prevented intraoperative nerve root injury that might have resulted in immediate onset of new neurologic deficits caused by the surgical procedure.
AB - Background Release of tethered spinal cord by sectioning of the filum terminale carries a significant risk of injury to the neighboring motor and sensory nerve roots. Intraoperative neurophysiological monitoring techniques can help to minimize these adverse neurologic outcomes. Methods We performed a retrospective review of 67 consecutive patients undergoing tethered cord release. We excluded 52 pediatric patients which limited our study to 15 adult patients treated during a four year period, including patients with a thick filum, low lying conus, myelomeningocele, filum tumor, spinal cord malformation, and/or lipoma. Clinical outcomes were determined from postoperative follow-up visits. Two patients were lost to follow up and were excluded from the clinical outcome analysis. Electrical stimulation of the filum terminale and lumbo-sacral nerve roots in conjunction with electromyogram (EMG) recording was performed intraoperatively. Results The mean electrical threshold for EMG response during stimulation of the filum terminale was 37.1 volts (V), range 15 to 100 V. In comparison, the lowest threshold obtained by direct stimulation of the ventral nerve roots was a mean of 1.46 V, with a range of 0.1 to 7 V. More than 70% of the patients studied demonstrated a filum to motor root threshold ratio of 100:1 or greater. No patient developed new neurologic symptoms or signs postoperatively. Bowel and bladder function improved in 46% of patients, back pain in 39% and motor function in 31%. Eight percent reported decline in bladder control and worsening back pain postoperatively. Conclusions The often dramatic difference in the threshold of the filum terminale and adjacent motor nerve roots (100:1) helps to identify, isolate, and safely section the filum terminale. Tethered cord release using intraoperative neurophysiological monitoring is safe and in the majority of cases leads to improvement or at least, stabilization of neurologic function. Monitoring prevented intraoperative nerve root injury that might have resulted in immediate onset of new neurologic deficits caused by the surgical procedure.
KW - Tethered cord syndrome
KW - adult presentation
KW - electrophysiology
KW - monitoring
KW - outcome
UR - http://www.scopus.com/inward/record.url?scp=3142740805&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=3142740805&partnerID=8YFLogxK
U2 - 10.1016/j.surneu.2003.11.025
DO - 10.1016/j.surneu.2003.11.025
M3 - Article
C2 - 15261505
AN - SCOPUS:3142740805
SN - 0090-3019
VL - 62
SP - 127
EP - 133
JO - Surgical neurology
JF - Surgical neurology
IS - 2
ER -