N2 - Objective: To evaluate the safety of computerized physician order entry (CPOE) and associated clinical decision support (CDS) systems in electronic health record (EHR) systems at pediatric inpatient facilities in the US using the Leapfrog Group's pediatric CPOE evaluation tool. Methods: The Leapfrog pediatric CPOE evaluation tool, a previously validated tool to assess the ability of a CPOE system to identify orders that could potentially lead to patient harm, was used to evaluate 41 pediatric hospitals over a 2-year period. Evaluation of the last available test for each institution was performed, assessing performance overall as well as by decision support category (eg, drug-drug, dosing limits). Longitudinal analysis of test performance was also carried out to assess the impact of testing and the overall trend of CPOE performance in pediatric hospitals. Results: Pediatric CPOE systems were able to identify 62% of potential medication errors in the test scenarios, but ranged widely from 23-91% in the institutions tested. The highest scoring categories included drug-allergy interactions, dosing limits (both daily and cumulative), and inappropriate routes of administration. We found that hospitals with longer periods since their CPOE implementation did not have better scores upon initial testing, but after initial testing there was a consistent improvement in testing scores of 4 percentage points per year. Conclusions: Pediatric computerized physician order entry (CPOE) systems on average are able to intercept a majority of potential medication errors, but vary widely among implementations. Prospective and repeated testing using the Leapfrog Group's evaluation tool is associated with improved ability to intercept potentialmedication errors.
AB - Objective: To evaluate the safety of computerized physician order entry (CPOE) and associated clinical decision support (CDS) systems in electronic health record (EHR) systems at pediatric inpatient facilities in the US using the Leapfrog Group's pediatric CPOE evaluation tool. Methods: The Leapfrog pediatric CPOE evaluation tool, a previously validated tool to assess the ability of a CPOE system to identify orders that could potentially lead to patient harm, was used to evaluate 41 pediatric hospitals over a 2-year period. Evaluation of the last available test for each institution was performed, assessing performance overall as well as by decision support category (eg, drug-drug, dosing limits). Longitudinal analysis of test performance was also carried out to assess the impact of testing and the overall trend of CPOE performance in pediatric hospitals. Results: Pediatric CPOE systems were able to identify 62% of potential medication errors in the test scenarios, but ranged widely from 23-91% in the institutions tested. The highest scoring categories included drug-allergy interactions, dosing limits (both daily and cumulative), and inappropriate routes of administration. We found that hospitals with longer periods since their CPOE implementation did not have better scores upon initial testing, but after initial testing there was a consistent improvement in testing scores of 4 percentage points per year. Conclusions: Pediatric computerized physician order entry (CPOE) systems on average are able to intercept a majority of potential medication errors, but vary widely among implementations. Prospective and repeated testing using the Leapfrog Group's evaluation tool is associated with improved ability to intercept potentialmedication errors.
KW - Computer simulation
KW - Computerized physician order entry
KW - Electronic health records
KW - Medication order entry
KW - Patient safety
KW - Software testing
UR - http://www.scopus.com/inward/record.url?scp=85016300255&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85016300255&partnerID=8YFLogxK
U2 - 10.1093/jamia/ocw134
DO - 10.1093/jamia/ocw134
M3 - Article
C2 - 27638908
AN - SCOPUS:85016300255
SN - 1067-5027
VL - 24
SP - 268
EP - 274
JO - Journal of the American Medical Informatics Association
JF - Journal of the American Medical Informatics Association
IS - 2
M1 - ocw134
ER -