TY - JOUR
T1 - Multi-organ comparison of flow-based arterial spin labeling techniques
T2 - Spatially non-selective labeling for cerebral and renal perfusion imaging
AU - Franklin, Suzanne L.
AU - Bones, Isabell K.
AU - Harteveld, Anita A.
AU - Hirschler, Lydiane
AU - van Stralen, Marijn
AU - Qin, Qin
AU - de Boer, Anneloes
AU - Hoogduin, Johannes M.
AU - Bos, Clemens
AU - van Osch, Matthias J.P.
AU - Schmid, Sophie
N1 - Funding Information:
This work is part of the research program Drag and Drop ASL with project number 14951, which is (partly) financed by the Netherlands Organization for Scientific Research (NWO). We thank MeVis Medical Solutions AG (Bremen, Germany) for providing MeVisLab medical image processing and visualization environment, which was used for image analysis.
Funding Information:
This work is part of the research program Drag and Drop ASL with project number 14951, which is (partly) financed by the Netherlands Organization for Scientific Research (NWO). We thank MeVis Medical Solutions AG (Bremen, Germany) for providing MeVisLab medical image processing and visualization environment, which was used for image analysis.
Publisher Copyright:
© 2020 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine
PY - 2021/5
Y1 - 2021/5
N2 - Purpose: Flow-based arterial spin labeling (ASL) techniques provide a transit-time insensitive alternative to the more conventional spatially selective ASL techniques. However, it is not clear which flow-based ASL technique performs best and also, how these techniques perform outside the brain (taking into account eg, flow-dynamics, field-inhomogeneity, and organ motion). In the current study we aimed to compare 4 flow-based ASL techniques (ie, velocity selective ASL, acceleration selective ASL, multiple velocity selective saturation ASL, and velocity selective inversion prepared ASL [VSI-ASL]) to the current spatially selective reference techniques in brain (ie, pseudo-continuous ASL [pCASL]) and kidney (ie, pCASL and flow alternating inversion recovery [FAIR]). Methods: Brain (n = 5) and kidney (n = 6) scans were performed in healthy subjects at 3T. Perfusion-weighted signal (PWS) maps were generated and ASL techniques were compared based on temporal SNR (tSNR), sensitivity to perfusion changes using a visual stimulus (brain) and robustness to respiratory motion by comparing scans acquired in paced-breathing and free-breathing (kidney). Results: In brain, all flow-based ASL techniques showed similar tSNR as pCASL, but only VSI-ASL showed similar sensitivity to perfusion changes. In kidney, all flow-based ASL techniques had comparable tSNR, although all lower than FAIR. In addition, VSI-ASL showed a sensitivity to B1-inhomogeneity. All ASL techniques were relatively robust to respiratory motion. Conclusion: In both brain and kidney, flow-based ASL techniques provide a planning-free and transit-time insensitive alternative to spatially selective ASL techniques. VSI-ASL shows the most potential overall, showing similar performance as the golden standard pCASL in brain. However, in kidney, a reduction of B1-sensitivity of VSI-ASL is necessary to match the performance of FAIR.
AB - Purpose: Flow-based arterial spin labeling (ASL) techniques provide a transit-time insensitive alternative to the more conventional spatially selective ASL techniques. However, it is not clear which flow-based ASL technique performs best and also, how these techniques perform outside the brain (taking into account eg, flow-dynamics, field-inhomogeneity, and organ motion). In the current study we aimed to compare 4 flow-based ASL techniques (ie, velocity selective ASL, acceleration selective ASL, multiple velocity selective saturation ASL, and velocity selective inversion prepared ASL [VSI-ASL]) to the current spatially selective reference techniques in brain (ie, pseudo-continuous ASL [pCASL]) and kidney (ie, pCASL and flow alternating inversion recovery [FAIR]). Methods: Brain (n = 5) and kidney (n = 6) scans were performed in healthy subjects at 3T. Perfusion-weighted signal (PWS) maps were generated and ASL techniques were compared based on temporal SNR (tSNR), sensitivity to perfusion changes using a visual stimulus (brain) and robustness to respiratory motion by comparing scans acquired in paced-breathing and free-breathing (kidney). Results: In brain, all flow-based ASL techniques showed similar tSNR as pCASL, but only VSI-ASL showed similar sensitivity to perfusion changes. In kidney, all flow-based ASL techniques had comparable tSNR, although all lower than FAIR. In addition, VSI-ASL showed a sensitivity to B1-inhomogeneity. All ASL techniques were relatively robust to respiratory motion. Conclusion: In both brain and kidney, flow-based ASL techniques provide a planning-free and transit-time insensitive alternative to spatially selective ASL techniques. VSI-ASL shows the most potential overall, showing similar performance as the golden standard pCASL in brain. However, in kidney, a reduction of B1-sensitivity of VSI-ASL is necessary to match the performance of FAIR.
KW - arterial spin labeling
KW - brain
KW - kidney
KW - perfusion imaging
KW - velocity selective ASL
UR - http://www.scopus.com/inward/record.url?scp=85096878703&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85096878703&partnerID=8YFLogxK
U2 - 10.1002/mrm.28603
DO - 10.1002/mrm.28603
M3 - Article
C2 - 33251644
AN - SCOPUS:85096878703
SN - 0740-3194
VL - 85
SP - 2580
EP - 2594
JO - Magnetic resonance in medicine
JF - Magnetic resonance in medicine
IS - 5
ER -