Monitor unit settings for intensity modulated beams delivered using a step-and-shoot approach

M. B. Sharpe, B. M. Miller, D. Yan, J. W. Wong

Research output: Contribution to journalArticlepeer-review

68 Scopus citations

Abstract

Two linear accelerators have been commissioned for delivering IMRT treatments using a step-and-shoot approach. To assess beam startup stability for 6 and 18 MV x-ray beams, dose delivered per monitor unit (MU), beam flatness, and beam symmetry were measured as a function of the total number of MU delivered at a clinical dose rate of 400 MU per minute. Relative to a 100 MU exposure, the dose delivered per MU by both linear accelerators was found to be within ±2% for exposures larger than 4 MU. Beam flatness and symmetry also met accepted quality assurance standards for a minimum exposure of 4 MU. We have found that the performance of the two machines under study is well suited to the delivery of step-and-shoot IMRT. A system of dose calculation has also been commissioned for applying head scatter corrections to fields as small as 1 x 1 cm2. The accuracy and precision of the relative output calculations in water was validated for small fields and fields offset from the axis of collimator rotation. For both 6 and 18 MV x-ray beams, the dose per MU calculated in a water phantom agrees with measured data to within 1% on average, with a maximum deviation of 2.5%. The largest output factor discrepancies were seen when the actual radiation field size deviated from the set field size. The measured output in water can vary by as much 16% for 1x1 cm2 fields, when the measured field size deviates from the set field size by 2 mm. For a 1 mm deviation, this discrepancy was reduced to 8%. Steps should be taken to ensure collimator precision is tightly controlled when using such small fields. If this is not possible, very small fields should not contribute to a significant portion of the treatment, or uncertainties in the collimator position may effect the accuracy of the dose delivered.

Original languageEnglish (US)
Pages (from-to)2719-2725
Number of pages7
JournalMedical physics
Volume27
Issue number12
DOIs
StatePublished - Jan 1 2000
Externally publishedYes

Keywords

  • Beam commissioning
  • Conformal radiotherapy
  • Dosimetry
  • IMRT
  • Intensity modulation
  • Multileaf collimator
  • Output factors
  • Quality assurance
  • Radiation therapy

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Monitor unit settings for intensity modulated beams delivered using a step-and-shoot approach'. Together they form a unique fingerprint.

Cite this