TY - JOUR
T1 - Miniaturized two-dimensional capillary electrophoresis on a microchip for analysis of the tryptic digest of proteins
AU - Cong, Yongzheng
AU - Zhang, Lihua
AU - Tao, Dingyin
AU - Liang, Yu
AU - Zhang, Weibing
AU - Zhang, Yukui
PY - 2008/2/1
Y1 - 2008/2/1
N2 - A two-dimensional capillary electrophoresis platform, combining isoelectric focusing (IEF) and capillary zone electrophoresis (CZE), was established on a microchip with the channel width and depth as 100 μm and 40 μm, respectively. With polyacrylamide as permanent coating, EOF in the microchannel, which could impair the separation, was decreased to 3.4 × 10-9m2 · V-1 · s-1, about 1/10 of that obtained in the uncoated set-up. During the separation, peptides were first focused by IEF in the first dimensional channel, and then directly driven into the perpendicular channel by controlling the applied voltages, and separated by CZE. Effects of various experimental parameters, including the electric field strength, channel length, and injection frequency from the first to the second dimensional separation channel, were studied. Under optimized condition, the digests of BSA and proteins extracted from E. coli were separated, and a peak capacity of 540 was obtained, which was far greater than that obtained by each single dimensional separation. All these results showed the promise of multidimensional separation on a microchip for the high-throughput and high-resolution analysis of complex samples.
AB - A two-dimensional capillary electrophoresis platform, combining isoelectric focusing (IEF) and capillary zone electrophoresis (CZE), was established on a microchip with the channel width and depth as 100 μm and 40 μm, respectively. With polyacrylamide as permanent coating, EOF in the microchannel, which could impair the separation, was decreased to 3.4 × 10-9m2 · V-1 · s-1, about 1/10 of that obtained in the uncoated set-up. During the separation, peptides were first focused by IEF in the first dimensional channel, and then directly driven into the perpendicular channel by controlling the applied voltages, and separated by CZE. Effects of various experimental parameters, including the electric field strength, channel length, and injection frequency from the first to the second dimensional separation channel, were studied. Under optimized condition, the digests of BSA and proteins extracted from E. coli were separated, and a peak capacity of 540 was obtained, which was far greater than that obtained by each single dimensional separation. All these results showed the promise of multidimensional separation on a microchip for the high-throughput and high-resolution analysis of complex samples.
KW - Microchip electrophoresis
KW - Peptides
KW - Permanent coating
KW - Separation voltage
KW - Two dimensional electrophoresis
UR - http://www.scopus.com/inward/record.url?scp=40449084582&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=40449084582&partnerID=8YFLogxK
U2 - 10.1002/jssc.200700444
DO - 10.1002/jssc.200700444
M3 - Article
C2 - 18219655
AN - SCOPUS:40449084582
SN - 1615-9306
VL - 31
SP - 588
EP - 594
JO - Journal of Separation Science
JF - Journal of Separation Science
IS - 3
ER -