TY - JOUR
T1 - Metal concentrations in electronic cigarette aerosol
T2 - Effect of open-system and closed-system devices and power settings
AU - Zhao, Di
AU - Navas Acien, Ana
AU - Ilievski, Vesna
AU - Slavkovich, Vesna
AU - Olmedo, Pablo
AU - Adria-Mora, Bernat
AU - Domingo-Relloso, Arce
AU - Aherrera, Angela
AU - Kleiman, Norman J.
AU - Rule, Ana M.
AU - Hilpert, Markus
N1 - Funding Information:
Research reported in this publication was supported by NIEHS and FDA Center for Tobacco Products (CTP) (grant 1R21ES029777-01 ). The content is solely the responsibility of the authors and does not necessarily represent the official views of the NIH or the Food and Drug Administration. Moreover, this study was supported by NIEHS grant P30 ES009089 and by a Johns Hopkins University Technology Transfer Seed Award. DZ was supported by the China Scholarship Council ( 201706190116 ). PO was supported by the Alfonso Martin Escudero Foundation (Postdoctoral Fellowship 2014). AA was supported by a grant from the Cigarette Restitution Fund (State of Maryland; grant PHPA-G2034 ).
Publisher Copyright:
© 2019 Elsevier Inc.
PY - 2019/7
Y1 - 2019/7
N2 - Background: Electronic cigarettes (E-cigarettes) generate aerosol containing metal contaminants. Our goals were to quantify aerosol metal concentrations and to compare the effects of power setting and device type (closed-system vs. open-system) on metal release. Methods: Aerosol samples were collected from two closed-system devices (a cigalike and pod) and two open-system devices (mods). Each open-system device was operated at three different power settings to examine the effect of device power on metal release. Concentrations of 14 metals in e-cigarette aerosol collected via droplet deposition were measured using inductively coupled plasma mass spectroscopy. Aerosol metal concentrations were reported as mass fractions (μg/kg) in the e-liquid. Results: For open-system device 1 (OD1), median arsenic (As), chromium (Cr), copper (Cu), iron (Fe), manganese (Mn), nickel (Ni), lead (Pb), antimony (Sb), tin (Sn), and zinc (Zn) concentrations increased 14, 54, 17, 30, 41, 96, 14, 81, 631, and 7-fold when the device power was increased from low (20 W) to intermediate (40 W) setting. When the power was further increased from intermediate (40 W) to high (80 W) setting, concentrations of As, Cr, Cu, Mn, Ni, and Sb did not change significantly. For open-system device 2 (OD2), Cr and Mn concentrations increased significantly when device power was increased from low (40 W) to intermediate (120 W) setting, and then decreased significantly when power was further increased from intermediate (120 W) to high (200 W) setting. Among the four devices, aerosol metal concentrations were higher for the open-system than the closed-system devices, except for aluminum (Al) and uranium (U). For Cr, median (interquartile range) concentrations (μg/kg) from the open-system devices were 2.51 (1.55, 4.23) and 15.6 (7.88, 54.5) vs. 0.39 (0.05, 0.72) and 0.41 (0.34, 0.57) for the closed-system devices. For Ni, concentrations (μg/kg) from the open-system devices were 793 (508, 1169) and 2148 (851, 3397) vs. 1.32 (0.39, 3.35) and 11.9 (10.7, 22.7) from the closed-system devices. Inhalation of 0% and 100% of samples from OD1, 7.4% and 88.9% from OD2 by typical e-cigarette users would exceed chronic minimum risk levels (MRL) of Mn and Ni, respectively. No MRL exceedance was predicted for the closed-system devices. A large fraction of users of OD1 (100%) and OD2 (77.8%) would be exposed to Ni levels higher than those from reference tobacco cigarette 3R4F. Conclusions: Our findings suggest that power setting and device type affect metal release from devices to aerosol which would subsequently be inhaled by users. Metal concentrations from open-system devices first increased with device power, and then leveled off for most metals. Open-system devices generate aerosol with higher metal concentrations than closed-system devices. These findings inform tobacco regulatory science, policy makers and health professionals on potential metal health risks associated with e-cigarette use, design and manufacturing.
AB - Background: Electronic cigarettes (E-cigarettes) generate aerosol containing metal contaminants. Our goals were to quantify aerosol metal concentrations and to compare the effects of power setting and device type (closed-system vs. open-system) on metal release. Methods: Aerosol samples were collected from two closed-system devices (a cigalike and pod) and two open-system devices (mods). Each open-system device was operated at three different power settings to examine the effect of device power on metal release. Concentrations of 14 metals in e-cigarette aerosol collected via droplet deposition were measured using inductively coupled plasma mass spectroscopy. Aerosol metal concentrations were reported as mass fractions (μg/kg) in the e-liquid. Results: For open-system device 1 (OD1), median arsenic (As), chromium (Cr), copper (Cu), iron (Fe), manganese (Mn), nickel (Ni), lead (Pb), antimony (Sb), tin (Sn), and zinc (Zn) concentrations increased 14, 54, 17, 30, 41, 96, 14, 81, 631, and 7-fold when the device power was increased from low (20 W) to intermediate (40 W) setting. When the power was further increased from intermediate (40 W) to high (80 W) setting, concentrations of As, Cr, Cu, Mn, Ni, and Sb did not change significantly. For open-system device 2 (OD2), Cr and Mn concentrations increased significantly when device power was increased from low (40 W) to intermediate (120 W) setting, and then decreased significantly when power was further increased from intermediate (120 W) to high (200 W) setting. Among the four devices, aerosol metal concentrations were higher for the open-system than the closed-system devices, except for aluminum (Al) and uranium (U). For Cr, median (interquartile range) concentrations (μg/kg) from the open-system devices were 2.51 (1.55, 4.23) and 15.6 (7.88, 54.5) vs. 0.39 (0.05, 0.72) and 0.41 (0.34, 0.57) for the closed-system devices. For Ni, concentrations (μg/kg) from the open-system devices were 793 (508, 1169) and 2148 (851, 3397) vs. 1.32 (0.39, 3.35) and 11.9 (10.7, 22.7) from the closed-system devices. Inhalation of 0% and 100% of samples from OD1, 7.4% and 88.9% from OD2 by typical e-cigarette users would exceed chronic minimum risk levels (MRL) of Mn and Ni, respectively. No MRL exceedance was predicted for the closed-system devices. A large fraction of users of OD1 (100%) and OD2 (77.8%) would be exposed to Ni levels higher than those from reference tobacco cigarette 3R4F. Conclusions: Our findings suggest that power setting and device type affect metal release from devices to aerosol which would subsequently be inhaled by users. Metal concentrations from open-system devices first increased with device power, and then leveled off for most metals. Open-system devices generate aerosol with higher metal concentrations than closed-system devices. These findings inform tobacco regulatory science, policy makers and health professionals on potential metal health risks associated with e-cigarette use, design and manufacturing.
KW - Aerosol
KW - Closed-system
KW - E-cigarettes
KW - Open-system
KW - Toxic metals
UR - http://www.scopus.com/inward/record.url?scp=85065060209&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85065060209&partnerID=8YFLogxK
U2 - 10.1016/j.envres.2019.04.003
DO - 10.1016/j.envres.2019.04.003
M3 - Article
C2 - 31071493
AN - SCOPUS:85065060209
SN - 0013-9351
VL - 174
SP - 125
EP - 134
JO - Environmental research
JF - Environmental research
ER -