TY - JOUR
T1 - Limitations of rapid HIV-1 tests during screening for trials in Uganda
T2 - Diagnostic test accuracy study
AU - Gray, Ronald H.
AU - Makumbi, Fredrick
AU - Serwadda, David
AU - Lutalo, Tom
AU - Nalugoda, Fred
AU - Opendi, Pius
AU - Kigozi, Godfrey
AU - Reynolds, Steven J.
AU - Sewankambo, Nelson K.
AU - Wawer, Maria J.
PY - 2007/7/28
Y1 - 2007/7/28
N2 - Objective: To evaluate the limitations of rapid tests for HIV-1. Design: Diagnostic test accuracy study. Setting: Rural Rakai, Uganda. Participants: 1517 males aged 15-49 screened for trials of circumcision for HIV prevention. Main outcome measures: Sensitivity, specificity, negative predictive values, and positive predictive values of an algorithm using three rapid tests for HIV, compared with the results of enzyme immunoassay and western blotting as the optimal methods. Results: Rapid test results were evaluated by enzyme immunoassay and western blotting. Sensitivity was 97.7%. Among 639 samples where the strength of positive bands was coded if the sample showed positivity for HIV, the algorithm had low specificity (94.1%) and a low positive predictive value (74.0%). Exclusion of 37 samples (5.8%) with a weak positive band improved the specificity (99.6%) and positive predictive value (97.7%). Conclusion: Weak positive bands on rapid tests for HIV should be confirmed by enzyme immunoassay and western blotting before disclosing the diagnosis. Programmes using rapid tests routinely should use standard serological assays for quality control. Trial registration: Clinical Trials NCT00425984.
AB - Objective: To evaluate the limitations of rapid tests for HIV-1. Design: Diagnostic test accuracy study. Setting: Rural Rakai, Uganda. Participants: 1517 males aged 15-49 screened for trials of circumcision for HIV prevention. Main outcome measures: Sensitivity, specificity, negative predictive values, and positive predictive values of an algorithm using three rapid tests for HIV, compared with the results of enzyme immunoassay and western blotting as the optimal methods. Results: Rapid test results were evaluated by enzyme immunoassay and western blotting. Sensitivity was 97.7%. Among 639 samples where the strength of positive bands was coded if the sample showed positivity for HIV, the algorithm had low specificity (94.1%) and a low positive predictive value (74.0%). Exclusion of 37 samples (5.8%) with a weak positive band improved the specificity (99.6%) and positive predictive value (97.7%). Conclusion: Weak positive bands on rapid tests for HIV should be confirmed by enzyme immunoassay and western blotting before disclosing the diagnosis. Programmes using rapid tests routinely should use standard serological assays for quality control. Trial registration: Clinical Trials NCT00425984.
UR - http://www.scopus.com/inward/record.url?scp=34547413615&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=34547413615&partnerID=8YFLogxK
U2 - 10.1136/bmj.39210.582801.BE
DO - 10.1136/bmj.39210.582801.BE
M3 - Article
C2 - 17545184
AN - SCOPUS:34547413615
SN - 0959-8146
VL - 335
SP - 188
EP - 190
JO - British Medical Journal
JF - British Medical Journal
IS - 7612
ER -