TY - JOUR
T1 - Learning-based deformable image registration
T2 - Effect of statistical mismatch between train and test images
AU - Ketcha, Michael D.
AU - De Silva, Tharindu
AU - Han, Runze
AU - Uneri, Ali
AU - Vogt, Sebastian
AU - Kleinszig, Gerhard
AU - Siewerdsen, Jeffrey H.
N1 - Funding Information:
The research was supported by NIH Grant No. R01-EB-017226 and collaboration with Siemens Healthineers.
Publisher Copyright:
© 2019 Society of Photo-Optical Instrumentation Engineers (SPIE).
PY - 2019/10/1
Y1 - 2019/10/1
N2 - Convolutional neural networks (CNNs) offer a promising means to achieve fast deformable image registration with accuracy comparable to conventional, physics-based methods. A persistent question with CNN methods, however, is whether they will be able to generalize to data outside of the training set. We investigated this question of mismatch between train and test data with respect to first- and second-order image statistics (e.g., spatial resolution, image noise, and power spectrum). A UNet-based architecture was built and trained on simulated CT images for various conditions of image noise (dose), spatial resolution, and deformation magnitude. Target registration error was measured as a function of the difference in statistical properties between the test and training data. Generally, registration error is minimized when the training data exactly match the statistics of the test data; however, networks trained with data exhibiting a diversity in statistical characteristics generalized well across the range of statistical conditions considered. Furthermore, networks trained on simulated image content with first- and second-order statistics selected to match that of real anatomical data were shown to provide reasonable registration performance on real anatomical content, offering potential new means for data augmentation. Characterizing the behavior of a CNN in the presence of statistical mismatch is an important step in understanding how these networks behave when deployed on new, unobserved data. Such characterization can inform decisions on whether retraining is necessary and can guide the data collection and/or augmentation process for training.
AB - Convolutional neural networks (CNNs) offer a promising means to achieve fast deformable image registration with accuracy comparable to conventional, physics-based methods. A persistent question with CNN methods, however, is whether they will be able to generalize to data outside of the training set. We investigated this question of mismatch between train and test data with respect to first- and second-order image statistics (e.g., spatial resolution, image noise, and power spectrum). A UNet-based architecture was built and trained on simulated CT images for various conditions of image noise (dose), spatial resolution, and deformation magnitude. Target registration error was measured as a function of the difference in statistical properties between the test and training data. Generally, registration error is minimized when the training data exactly match the statistics of the test data; however, networks trained with data exhibiting a diversity in statistical characteristics generalized well across the range of statistical conditions considered. Furthermore, networks trained on simulated image content with first- and second-order statistics selected to match that of real anatomical data were shown to provide reasonable registration performance on real anatomical content, offering potential new means for data augmentation. Characterizing the behavior of a CNN in the presence of statistical mismatch is an important step in understanding how these networks behave when deployed on new, unobserved data. Such characterization can inform decisions on whether retraining is necessary and can guide the data collection and/or augmentation process for training.
KW - convolutional neural networks
KW - deformable image registration
KW - image quality
UR - http://www.scopus.com/inward/record.url?scp=85077492225&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85077492225&partnerID=8YFLogxK
U2 - 10.1117/1.JMI.6.4.044008
DO - 10.1117/1.JMI.6.4.044008
M3 - Article
C2 - 31853461
AN - SCOPUS:85077492225
SN - 2329-4302
VL - 6
JO - Journal of Medical Imaging
JF - Journal of Medical Imaging
IS - 4
M1 - 044008
ER -