Abstract
Rapid and sensitive quantitation of antipyrine in plasma is achieved by high-presure liquid chromatography. Antipyrine and phenacetin, the internal standard, are readily extracted from alkalinized plasma into ethyl acetate. After evaporation of the organic solvent, the redissolved residue is chromatographed using a reverse-phase C-18 column. The sensitivity limit is approximately 0.25 μg antipyrine per ml plasma, with a coefficient of variation for identical samples not exceeding 3%. Using the automated sampling system, one person can analyze up to 100 samples per day. The method is reliable and sensitive enough to allow human pharmacokinetic studies of antipyrine using doses considerably less than utilized in previous studies. The disposition kinetics of a single i.v. dose of antipyrine in four human volunteers were essentially identical over a 5-fold ranges of doses.
| Original language | English (US) |
|---|---|
| Pages (from-to) | 51-55 |
| Number of pages | 5 |
| Journal | International Journal of Clinical Pharmacology Therapy and Toxicology |
| Volume | 21 |
| Issue number | 2 |
| State | Published - 1983 |
| Externally published | Yes |
ASJC Scopus subject areas
- Toxicology
- Pharmacology (medical)
Fingerprint
Dive into the research topics of 'Kinetics of low-dose intravenous antipyrine: Use of liquid chromatography'. Together they form a unique fingerprint.Cite this