Abstract
A simple and easy technique for inserting an iris fixation suture for use with a four-loop Binkhorst lens is described. The preplaced 10-0 Prolene fixation suture permits pupillary dilatation after the insertion of a four-loop Binkhorst lens and prevents inadvertent dislocation of the lens.
Original language | English (US) |
---|---|
Pages (from-to) | 121-123 |
Number of pages | 3 |
Journal | Ophthalmic Surgery |
Volume | 11 |
Issue number | 2 |
State | Published - Jan 1 1980 |