TY - JOUR
T1 - Integration of Sensor-Based and Self-Reported Metrics in a Sleep Diary
T2 - A Pilot Exploration
AU - Conklin, Sarah
AU - Dietch, Jessica R.
AU - Kargosha, Golshan
AU - Luyster, Faith
AU - Atwood, Molly
AU - Tenan, Matthew S.
AU - Zammit, Gary
AU - Banerjee, Nilanjan
AU - Brooks, Justin
N1 - Publisher Copyright:
© 2024 Taylor & Francis Group, LLC.
PY - 2024
Y1 - 2024
N2 - Objectives: Discrepancies between sleep diaries and sensor-based sleep parameters are widely recognized. This study examined the effect of showing sensor-based sleep parameters while completing a daily diary. The provision of sensor-based data was expected to reduce variance but not change the mean of self-reported sleep parameters, which would in turn align better with sensor-based data compared to a control diary. Method: In a crossover study, 24 volunteers completed week-long periods of control diary (digital sleep diary without sensor-based data feedback) or integrated diary (diary with device feedback), washout, and then the other diary condition. Results: The integrated diary reduced self-reported total sleep time (TST) by <10 minutes and reduced variance in TST. The integrated diary did not impact mean sleep onset latency (SOL) and, unexpectedly, the variance in SOL increased. The integrated diary improved both bias and limits of agreement for SOL and TST. Conclusions: Integration of wearable, sensor-based device data in a sleep diary has little impact on means, mixed evidence for less variance, and better agreement with sensor-based data than a traditional diary. How the diary impacts reporting and sensor-based sleep measurements should be explored.
AB - Objectives: Discrepancies between sleep diaries and sensor-based sleep parameters are widely recognized. This study examined the effect of showing sensor-based sleep parameters while completing a daily diary. The provision of sensor-based data was expected to reduce variance but not change the mean of self-reported sleep parameters, which would in turn align better with sensor-based data compared to a control diary. Method: In a crossover study, 24 volunteers completed week-long periods of control diary (digital sleep diary without sensor-based data feedback) or integrated diary (diary with device feedback), washout, and then the other diary condition. Results: The integrated diary reduced self-reported total sleep time (TST) by <10 minutes and reduced variance in TST. The integrated diary did not impact mean sleep onset latency (SOL) and, unexpectedly, the variance in SOL increased. The integrated diary improved both bias and limits of agreement for SOL and TST. Conclusions: Integration of wearable, sensor-based device data in a sleep diary has little impact on means, mixed evidence for less variance, and better agreement with sensor-based data than a traditional diary. How the diary impacts reporting and sensor-based sleep measurements should be explored.
UR - http://www.scopus.com/inward/record.url?scp=85195684648&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85195684648&partnerID=8YFLogxK
U2 - 10.1080/15402002.2024.2359413
DO - 10.1080/15402002.2024.2359413
M3 - Article
C2 - 38867429
AN - SCOPUS:85195684648
SN - 1540-2002
JO - Behavioral Sleep Medicine
JF - Behavioral Sleep Medicine
ER -