TY - JOUR
T1 - Integration of cone-beam CT in stereotactic body radiation therapy
AU - Yin, Fang Fang
AU - Wang, Zhiheng
AU - Yoo, Sua
AU - Wu, Q. Jackie
AU - Kirkpatrick, John
AU - Larrier, Nicole
AU - Meyer, Jeffrey
AU - Willett, Christopher G.
AU - Marks, Lawrence B.
PY - 2008/4
Y1 - 2008/4
N2 - This report describes the technique and initial experience using cone beam CT (CBCT) for localization of treatment targets in patients undergoing stereotactic body radiation therapy (SBRT). Patients selected for SBRT underwent 3-D or 4-D CT scans in a customized immobilization cradle. GTV, CTV, ITV, and PTV were defined. Intensity-modulated radiation beams, multiple 3-D conformal beams, or dynamic conformal arcs were delivered using a Varian 21EX with 120-leaf MLC. CBCT images were obtained prior to each fraction, and registered to the planning CT by using soft tissue and bony structures to assure accurate isocenter localization. Patients were repositioned for treatment based on the CBCT images. Radiographic images (kV, MV, or CBCT) were taken before and after beam delivery to further assess set-up accuracy. Ten patients with lung, liver, and spine lesions received 29 fractions of treatment using this technique. The prescription doses ranged 1250 - 6000 cGy in 1 - 5 fractions. Compared to traditional 2-D matching using bony structures, CBCT corrects target deviation from 1 mm to 15 mm, with an average of 5 mm. Comparison of pre-treatment to post-treatment radiographic images demonstrated an average 2 mm deviation (ranging from 0-4 mm). Improved immobilization may enhance positioning accuracy. Typical total "in-room" times for the patients are approximately 1 hour. CBCT-guided SBRT is feasible and enhances setup accuracy using 3-D anatomical information.
AB - This report describes the technique and initial experience using cone beam CT (CBCT) for localization of treatment targets in patients undergoing stereotactic body radiation therapy (SBRT). Patients selected for SBRT underwent 3-D or 4-D CT scans in a customized immobilization cradle. GTV, CTV, ITV, and PTV were defined. Intensity-modulated radiation beams, multiple 3-D conformal beams, or dynamic conformal arcs were delivered using a Varian 21EX with 120-leaf MLC. CBCT images were obtained prior to each fraction, and registered to the planning CT by using soft tissue and bony structures to assure accurate isocenter localization. Patients were repositioned for treatment based on the CBCT images. Radiographic images (kV, MV, or CBCT) were taken before and after beam delivery to further assess set-up accuracy. Ten patients with lung, liver, and spine lesions received 29 fractions of treatment using this technique. The prescription doses ranged 1250 - 6000 cGy in 1 - 5 fractions. Compared to traditional 2-D matching using bony structures, CBCT corrects target deviation from 1 mm to 15 mm, with an average of 5 mm. Comparison of pre-treatment to post-treatment radiographic images demonstrated an average 2 mm deviation (ranging from 0-4 mm). Improved immobilization may enhance positioning accuracy. Typical total "in-room" times for the patients are approximately 1 hour. CBCT-guided SBRT is feasible and enhances setup accuracy using 3-D anatomical information.
KW - And hypofractionation
KW - Cone-beam CT
KW - Extracranial radiosurgery
KW - Image-guided radiation therapy
KW - Stereotactic body radiation therapy
UR - http://www.scopus.com/inward/record.url?scp=42349110698&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=42349110698&partnerID=8YFLogxK
U2 - 10.1177/153303460800700206
DO - 10.1177/153303460800700206
M3 - Article
C2 - 18345702
AN - SCOPUS:42349110698
SN - 1533-0346
VL - 7
SP - 133
EP - 139
JO - Technology in Cancer Research and Treatment
JF - Technology in Cancer Research and Treatment
IS - 2
ER -