Imaging Aerosol Deposition with Two-Dimensional Gamma Scintigraphy

Research output: Contribution to journalReview articlepeer-review

Abstract

Several imaging modalities have been employed to quantify lung dose and the distribution of the dose of orally inhaled aerosols in vivo. Two-dimensional (2D, or planar) imaging using gamma scintigraphy is the most widely used of these modalities. Two-dimensional gamma scintigraphy studies are accomplished using a single- or dual-headed gamma camera. The formulation to be tested is admixed with the gamma emitting radioisotope 99mtechnetium, which serves as a surrogate for the drug. This article provides details as to how 2D gamma scintigraphy images should be acquired and analyzed using recently standardized methods. Based on the new guidelines, the investigator should confirm that the drug formulation is unchanged with the addition of the radioisotope, determine the amount of radioactivity needed for inhalation to obtain appropriate radioactivity counts in the lungs, perform quality control procedures for the gamma camera, identify the lung borders of the study subject using a reference image such as an X-ray computed tomography scan, a ventilation scan, or a transmission scan, acquire a lung transmission image to correct for attenuation of radioactivity by lung tissue, instruct the subject how to inhale the radiolabel-drug mixture and record associated breathing parameters, acquire anterior and/or posterior views of the lungs and any other regions of interest (i.e., oropharynx, stomach) and assess the acquired images for total and regional dose to the lungs. Total dose should be assessed after identification of the right lung border and appropriate correction for tissue attenuation. Regional dose should be quantified as a normalized outer/inner deposition ratio (O/I) and expressed as the penetration index (PI). Mass balance should be performed as needed. By following the standardized methods, 2D gamma scintigraphy data from studies in different laboratories may be compared and combined, leading to multi-center studies and more rapid development of new medications and devices for inhaled therapies.

Original languageEnglish (US)
Pages (from-to)333-341
Number of pages9
JournalJournal of aerosol medicine and pulmonary drug delivery
Volume35
Issue number6
DOIs
StatePublished - Dec 1 2022

Keywords

  • 2D gamma scintigraphy
  • aerosol deposition
  • lung imaging
  • orally-inhaled products

ASJC Scopus subject areas

  • Pulmonary and Respiratory Medicine
  • Pharmaceutical Science
  • Pharmacology (medical)

Fingerprint

Dive into the research topics of 'Imaging Aerosol Deposition with Two-Dimensional Gamma Scintigraphy'. Together they form a unique fingerprint.

Cite this