Skip to main navigation Skip to search Skip to main content

Image-based compensation for involuntary motion in weight-bearing C-arm cone-beam CT scanning of knees

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

We previously introduced four fiducial marker-based strategies to compensate for involuntary knee-joint motion during weight-bearing C-arm CT scanning of the lower body. 2D methods showed significant reduction of motion-related artifacts, but 3D methods worked best. However, previous methods led to increased examination times and patient discomfort caused by the marker attachment process. Moreover, sub-optimal marker placement may lead to decreased marker detectability and therefore unstable motion estimates. In order to reduce overall patient discomfort, we developed a new image-based 2D projection shifting method. A C-arm cone-beam CT system was used to acquire projection images of five healthy volunteers at various flexion angles. Projection matrices for the horizontal scanning trajectory were calibrated using the Siemens standard PDS-2 phantom. The initial reconstruction was forward projected using maximum-intensity projections (MIP), yielding an estimate of a static scan. This estimate was then used to obtain the 2D projection shifts via registration. For the scan with the most motion, the proposed method reproduced the marker-based results with a mean error of 2.90 mm +/-1.43 mm (compared to a mean error of 4.10 mm +/-3.03 mm in the uncorrected case). Bone contour surrounding modeling clay layer was improved. The proposed method is a first step towards automatic image-based, marker-free motion-compensation.

Original languageEnglish (US)
Title of host publicationMedical Imaging 2015
Subtitle of host publicationImage Processing
EditorsMartin A. Styner, Sebastien Ourselin
PublisherSPIE
ISBN (Electronic)9781628415032
DOIs
StatePublished - 2015
Externally publishedYes
EventMedical Imaging 2015: Image Processing - Orlando, United States
Duration: Feb 24 2015Feb 26 2015

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume9413
ISSN (Print)1605-7422

Other

OtherMedical Imaging 2015: Image Processing
Country/TerritoryUnited States
CityOrlando
Period2/24/152/26/15

Keywords

  • C-arm cone-beam CT
  • fiducial marker
  • image-based motion compensation
  • medical image processing
  • motion artifacts
  • mutual information
  • weight-bearing knee

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Atomic and Molecular Physics, and Optics
  • Biomaterials
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Image-based compensation for involuntary motion in weight-bearing C-arm cone-beam CT scanning of knees'. Together they form a unique fingerprint.

Cite this