TY - JOUR
T1 - How to reduce head CT orders in children with hydrocephalus using the lean six sigma methodology
T2 - Experience at a major quaternary care academic children's center
AU - Tekes, A.
AU - Jackson, E. M.
AU - Ogborn, J.
AU - Liang, S.
AU - Bledsoe, M.
AU - Durand, D. J.
AU - Jallo, G.
AU - Huisman, T. A.G.M.
PY - 2016/6
Y1 - 2016/6
N2 - BACKGROUND AND PURPOSE: Lean Six Sigma methodology is increasingly used to drive improvement in patient safety, quality of care, and cost-effectiveness throughout the US health care delivery system. To demonstrate our value as specialists, radiologists can combine lean methodologies along with imaging expertise to optimize imaging elements-of-care pathways. In this article, we describe a Lean Six Sigma project with the goal of reducing the relative use of pediatric head CTs in our population of patients with hydrocephalus by 50% within 6 months. MATERIALS AND METHODS: We applied a Lean Six Sigma methodology using a multidisciplinary team at a quaternary care academic children's center. The existing baseline imaging practice for hydrocephalus was outlined in a Kaizen session, and potential interventions were discussed. An improved radiation-free workflow with ultrafast MR imaging was created. Baseline data were collected for 3 months by using the departmental radiology information system. Data collection continued postintervention and during the control phase (each for 3 months). The percentage of neuroimaging per technique (head CT, head ultrasound, ultrafast brain MR imaging, and routine brain MR imaging) was recorded during each phase. RESULTS: The improved workflow resulted in a 75% relative reduction in the percentage of hydrocephalus imaging performed by CT between the pre- and postintervention/control phases (Z-test, P = .0001). CONCLUSIONS: Our lean interventions in the pediatric hydrocephalus care pathway resulted in a significant reduction in head CT orders and increased use of ultrafast brain MR imaging.
AB - BACKGROUND AND PURPOSE: Lean Six Sigma methodology is increasingly used to drive improvement in patient safety, quality of care, and cost-effectiveness throughout the US health care delivery system. To demonstrate our value as specialists, radiologists can combine lean methodologies along with imaging expertise to optimize imaging elements-of-care pathways. In this article, we describe a Lean Six Sigma project with the goal of reducing the relative use of pediatric head CTs in our population of patients with hydrocephalus by 50% within 6 months. MATERIALS AND METHODS: We applied a Lean Six Sigma methodology using a multidisciplinary team at a quaternary care academic children's center. The existing baseline imaging practice for hydrocephalus was outlined in a Kaizen session, and potential interventions were discussed. An improved radiation-free workflow with ultrafast MR imaging was created. Baseline data were collected for 3 months by using the departmental radiology information system. Data collection continued postintervention and during the control phase (each for 3 months). The percentage of neuroimaging per technique (head CT, head ultrasound, ultrafast brain MR imaging, and routine brain MR imaging) was recorded during each phase. RESULTS: The improved workflow resulted in a 75% relative reduction in the percentage of hydrocephalus imaging performed by CT between the pre- and postintervention/control phases (Z-test, P = .0001). CONCLUSIONS: Our lean interventions in the pediatric hydrocephalus care pathway resulted in a significant reduction in head CT orders and increased use of ultrafast brain MR imaging.
UR - http://www.scopus.com/inward/record.url?scp=84974575028&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84974575028&partnerID=8YFLogxK
U2 - 10.3174/ajnr.A4658
DO - 10.3174/ajnr.A4658
M3 - Article
C2 - 26797143
AN - SCOPUS:84974575028
SN - 0195-6108
VL - 37
SP - 990
EP - 996
JO - American Journal of Neuroradiology
JF - American Journal of Neuroradiology
IS - 6
ER -