TY - JOUR
T1 - High interocular corneal symmetry in average simulated keratometry, central corneal thickness, and posterior elevation
AU - Myrowitz, Elliott H.
AU - Kouzis, Anthony C.
AU - O'Brien, Terrence P.
PY - 2005/5/1
Y1 - 2005/5/1
N2 - Purpose. The purpose of this study was to assess interocular corneal symmetry in average simulated keratometry, corneal thickness, and posterior corneal elevation. Methods. This retrospective analysis included data from scanning slit topography (Orbscan II; Bausch and Lomb, Rochester, NY) on 242 eyes from 121 consecutive patients undergoing standard evaluation for consideration of elective laser vision correction. The symmetry between the right and left eye in average simulated keratometry, minimum central corneal thickness, and posterior corneal elevation was assessed by comparative data analysis. Results. Simulated keratometry ranged from 39.9 to 48.6 D. The interocular difference in average simulated keratometry was 0.47 D (standard deviation [SD] 0.43). The interocular Pearson correlation coefficient for average simulated keratometry was 0.90 (p < 0.001). The range of minimum corneal thickness was 432 to 628 μm. The interocular Pearson correlation coefficient for minimum central corneal thickness was 0.95 (p < 0.001). Right and left eye minimum corneal thickness differed by an average 8 μm (SD 7). The range of posterior elevation was -4 to 54 μm. The average difference in posterior corneal elevation between the right and left eye was 6 μm (SD 5). The interocular Pearson correlation coefficient for posterior corneal elevation was 0.72 (p < 0.001). The average posterior elevation was 19 μm (SD 11). Conclusions. Although a wide range of values exists in simulated keratometry, minimum corneal thickness, and posterior corneal elevation, interocular symmetry in all these parameters was very high in this group of consecutive patients. Asymmetry of these interocular parameters may warrant repeat clinical testing for accuracy and may predict corneal abnormalities. Normative data on posterior cornea elevation is presented. This study points out potentially clinically important high interocular corneal symmetry data in simulated keratometry, corneal thickness, and posterior corneal elevation.
AB - Purpose. The purpose of this study was to assess interocular corneal symmetry in average simulated keratometry, corneal thickness, and posterior corneal elevation. Methods. This retrospective analysis included data from scanning slit topography (Orbscan II; Bausch and Lomb, Rochester, NY) on 242 eyes from 121 consecutive patients undergoing standard evaluation for consideration of elective laser vision correction. The symmetry between the right and left eye in average simulated keratometry, minimum central corneal thickness, and posterior corneal elevation was assessed by comparative data analysis. Results. Simulated keratometry ranged from 39.9 to 48.6 D. The interocular difference in average simulated keratometry was 0.47 D (standard deviation [SD] 0.43). The interocular Pearson correlation coefficient for average simulated keratometry was 0.90 (p < 0.001). The range of minimum corneal thickness was 432 to 628 μm. The interocular Pearson correlation coefficient for minimum central corneal thickness was 0.95 (p < 0.001). Right and left eye minimum corneal thickness differed by an average 8 μm (SD 7). The range of posterior elevation was -4 to 54 μm. The average difference in posterior corneal elevation between the right and left eye was 6 μm (SD 5). The interocular Pearson correlation coefficient for posterior corneal elevation was 0.72 (p < 0.001). The average posterior elevation was 19 μm (SD 11). Conclusions. Although a wide range of values exists in simulated keratometry, minimum corneal thickness, and posterior corneal elevation, interocular symmetry in all these parameters was very high in this group of consecutive patients. Asymmetry of these interocular parameters may warrant repeat clinical testing for accuracy and may predict corneal abnormalities. Normative data on posterior cornea elevation is presented. This study points out potentially clinically important high interocular corneal symmetry data in simulated keratometry, corneal thickness, and posterior corneal elevation.
KW - Central corneal thickness
KW - Corneal symmetry
KW - Orbscan
KW - Pachymetry
KW - Posterior corneal elevation
KW - Simulated keratometry
KW - Topography
UR - http://www.scopus.com/inward/record.url?scp=18644373590&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=18644373590&partnerID=8YFLogxK
U2 - 10.1097/01.OPX.0000162666.83092.E4
DO - 10.1097/01.OPX.0000162666.83092.E4
M3 - Article
C2 - 15894919
AN - SCOPUS:18644373590
SN - 1040-5488
VL - 82
SP - 428
EP - 431
JO - Optometry and Vision Science
JF - Optometry and Vision Science
IS - 5
ER -