High interocular corneal symmetry in average simulated keratometry, central corneal thickness, and posterior elevation

Elliott H. Myrowitz, Anthony C. Kouzis, Terrence P. O'Brien

Research output: Contribution to journalArticlepeer-review

36 Scopus citations

Abstract

Purpose. The purpose of this study was to assess interocular corneal symmetry in average simulated keratometry, corneal thickness, and posterior corneal elevation. Methods. This retrospective analysis included data from scanning slit topography (Orbscan II; Bausch and Lomb, Rochester, NY) on 242 eyes from 121 consecutive patients undergoing standard evaluation for consideration of elective laser vision correction. The symmetry between the right and left eye in average simulated keratometry, minimum central corneal thickness, and posterior corneal elevation was assessed by comparative data analysis. Results. Simulated keratometry ranged from 39.9 to 48.6 D. The interocular difference in average simulated keratometry was 0.47 D (standard deviation [SD] 0.43). The interocular Pearson correlation coefficient for average simulated keratometry was 0.90 (p < 0.001). The range of minimum corneal thickness was 432 to 628 μm. The interocular Pearson correlation coefficient for minimum central corneal thickness was 0.95 (p < 0.001). Right and left eye minimum corneal thickness differed by an average 8 μm (SD 7). The range of posterior elevation was -4 to 54 μm. The average difference in posterior corneal elevation between the right and left eye was 6 μm (SD 5). The interocular Pearson correlation coefficient for posterior corneal elevation was 0.72 (p < 0.001). The average posterior elevation was 19 μm (SD 11). Conclusions. Although a wide range of values exists in simulated keratometry, minimum corneal thickness, and posterior corneal elevation, interocular symmetry in all these parameters was very high in this group of consecutive patients. Asymmetry of these interocular parameters may warrant repeat clinical testing for accuracy and may predict corneal abnormalities. Normative data on posterior cornea elevation is presented. This study points out potentially clinically important high interocular corneal symmetry data in simulated keratometry, corneal thickness, and posterior corneal elevation.

Original languageEnglish (US)
Pages (from-to)428-431
Number of pages4
JournalOptometry and Vision Science
Volume82
Issue number5
DOIs
StatePublished - May 1 2005

Keywords

  • Central corneal thickness
  • Corneal symmetry
  • Orbscan
  • Pachymetry
  • Posterior corneal elevation
  • Simulated keratometry
  • Topography

ASJC Scopus subject areas

  • Ophthalmology
  • Optometry

Fingerprint

Dive into the research topics of 'High interocular corneal symmetry in average simulated keratometry, central corneal thickness, and posterior elevation'. Together they form a unique fingerprint.

Cite this