Hematologic toxicity in radioimmunotherapy: Dose-response relationships for I-131 labeled antibody therapy

Joseph A. O'Donoghue, Nana Efua Baidoo, Devie Deland, Sydney Welt, Chaitanya R. Divgi, George Sgouros

Research output: Contribution to journalArticlepeer-review

38 Scopus citations

Abstract

Bone marrow toxicity is generally dose-limiting for radioimmunotherapy (RIT) with β-emitting radionuclides. Treatment may be prescribed on the basis of administered activity or absorbed dose. An optimal definition of maximum tolerated dose will enable the clinical benefits of RIT to be maximized. Methods We examined data from six clinical studies of RIT with various 131-1 labeled antibodies and antibody fragments that treated a total of J14 patients. We also examined a sub-set of 36 patients with minimal prior chemotherapy who were treated with-labeled intact murine IgG at a single institution. For both these groups the ability of absorbed dose-based methods to predict bone marrow tolerance was compared with that of activity-based methods. Results Marrow toxicity was more accurately predicted by absorbed dose than by activity in the general case where a variety of different antibodies and antibody fragments were used. For the more homogeneous smaller group, well defined "dose-response " relationships were observed for both absorbed dose and administered activity. However, absorbed dose-based definitions of maximally tolerated dose yielded a better stratification of patients than activity-based definitions (including per meter squared) such that fewer patients had major toxicity when treated below "tolerance", and fewer patients had minor toxicity when treated above "tolerance". Conclusions Absorbed dose-based definitions of maximum tolerated dose and escalation variables are optimal for 1311-labeled antibody therapy. The ability of pre-therapy dosimetry studies to predict the behavior of therapeutic administrations must be validated for prospective clinical applications.

Original languageEnglish (US)
Pages (from-to)435-443
Number of pages9
JournalCancer Biotherapy and Radiopharmaceuticals
Volume17
Issue number4
DOIs
StatePublished - Jan 1 2002
Externally publishedYes

Keywords

  • Absorbed dose
  • Dose response
  • Radioimmunotherapy
  • Thrombocytopenia
  • Toxicity

ASJC Scopus subject areas

  • Oncology
  • Radiology Nuclear Medicine and imaging
  • Pharmacology
  • Cancer Research

Fingerprint

Dive into the research topics of 'Hematologic toxicity in radioimmunotherapy: Dose-response relationships for I-131 labeled antibody therapy'. Together they form a unique fingerprint.

Cite this