Gibbs ringing artifact

David Bonekamp, Stefan L. Zimmerman

Research output: Chapter in Book/Report/Conference proceedingChapter

Abstract

Imaging description The Gibbs ringing artifact (truncation artifact) results from the limited fidelity of the superimposition of a finite number of sine and cosine functions to exactly reproduce a sharp border. In cardiac MR, it usually occurs as dark and bright periodic rings with decreasing amplitude at increased distance from the blood–myocardial border. It is the more noticeable the higher the contrast between blood and myocardium, and thus is especially prominent in first-pass perfusion studies during the early frames, where high ventricular contrast concentrations meet essentially unenhanced myocardium (Figure 49.1).Importance The Gibbs artifact causes oscillations around the sharp highcontrast blood/myocardial border. It results from the mathematical properties of the representation of MR images as a Fourier series, which can only approximate sharp borders. It can be made arbitrarily small at the cost of imaging time by increasing spatial resolution; however, it can never be fully avoided. The resulting image will show edges with adjacent ringing in the form of a sinc function (sin x/x). The artifact is present in both the frequency and phase directions. Mathematically, it can be shown that the positive and negative side lobes of the Fourier series have approximately 9% deviation from the baseline, thus resulting in a possible 18% deviation of signal in the subendocardium on perfusion studies if pixels are reconstructed exactly in the hills and valleys of these oscillations. This is in the range of mild perfusion defects and has important clinical consequences. These artifacts may either mask true underlying early perfusion defects or mimic such defects, leading either to decreased sensitivity for perfusion abnormalities or inappropriate diagnosis of a perfusion defect. Both Gibbs artifact and ischemia affect the subendocardial myocardium preferentially compared to the mid-or subepicardial myocardium (Figure 49.2). Thus, it can be a challenge distinguishing these from each other; and MR sequences should be optimized to minimize Gibbs artifact. By the same mechanism, Gibbs ringing can lead to simulation of a syrinx in the spinal cord or cause ringing artifact around vessels in MR angiographic examinations.

Original languageEnglish (US)
Title of host publicationPearls and Pitfalls in Cardiovascular Imaging
Subtitle of host publicationPseudolesions, Artifacts and Other Difficult Diagnoses
PublisherCambridge University Press
Pages154-158
Number of pages5
ISBN (Electronic)9781139152228
ISBN (Print)9781107023727
DOIs
StatePublished - Jan 1 2015

ASJC Scopus subject areas

  • Medicine(all)

Fingerprint

Dive into the research topics of 'Gibbs ringing artifact'. Together they form a unique fingerprint.

Cite this