TY - JOUR
T1 - Extended composite temporoparietal fascial flap
T2 - Clinical implications for tissue engineering in mandibular reconstruction
AU - Patel, Parit A.
AU - Chen, Wendy
AU - Wilkening, Matthew
AU - Uribe-Rivera, Armando
AU - Racadio, John M.
AU - Gordon, Christopher B.
PY - 2013/1/1
Y1 - 2013/1/1
N2 - BACKGROUND: The authors have expanded upon a well-described and widely used flap in the head and neck region. The purpose of the cadaver study was to determine the feasibility, angiosome, and the potential application of this pedicled flap in bone tissue engineering of the mandible. METHODS: A total of 6 fresh human cadaver heads were dissected for a total of 12 flaps. The extended composite temporoparietal fascial flap, based on the superficial temporal artery (STA) and including cranial periosteum, was dissected and the dimensions were measured. Through a combined submandibular and preauricular incision, the mandible was exposed and the dimensions were measured from the sigmoid notch to the gonion angle and from the gonion angle to the symphysis. CT angiography and silicone injections were performed to identify the vascular anatomy of the flap. RESULTS: The combined distance from the sigmoid notch to the gonion and the gonion to the symphysis, plotted versus the cranial apex to tragus length, demonstrated adequate flap dimensions in all specimens for hemi-mandibular reconstruction. The average flap length was 16.5 ± 1.40 cm and the average flap width was 11.4 ± 0.98 cm, resulting in an average flap surface area of 94.5 ± 13.08 cm. Radiographic images and silicone injections confirmed STA perfusion of the cranial periosteum. CONCLUSIONS: The extended composite temporoparietal fascial flap with periosteum can be a viable option for providing vascularized periosteum in tissue-engineered craniofacial reconstruction.
AB - BACKGROUND: The authors have expanded upon a well-described and widely used flap in the head and neck region. The purpose of the cadaver study was to determine the feasibility, angiosome, and the potential application of this pedicled flap in bone tissue engineering of the mandible. METHODS: A total of 6 fresh human cadaver heads were dissected for a total of 12 flaps. The extended composite temporoparietal fascial flap, based on the superficial temporal artery (STA) and including cranial periosteum, was dissected and the dimensions were measured. Through a combined submandibular and preauricular incision, the mandible was exposed and the dimensions were measured from the sigmoid notch to the gonion angle and from the gonion angle to the symphysis. CT angiography and silicone injections were performed to identify the vascular anatomy of the flap. RESULTS: The combined distance from the sigmoid notch to the gonion and the gonion to the symphysis, plotted versus the cranial apex to tragus length, demonstrated adequate flap dimensions in all specimens for hemi-mandibular reconstruction. The average flap length was 16.5 ± 1.40 cm and the average flap width was 11.4 ± 0.98 cm, resulting in an average flap surface area of 94.5 ± 13.08 cm. Radiographic images and silicone injections confirmed STA perfusion of the cranial periosteum. CONCLUSIONS: The extended composite temporoparietal fascial flap with periosteum can be a viable option for providing vascularized periosteum in tissue-engineered craniofacial reconstruction.
KW - Bone tissue engineering
KW - mandibular reconstruction
KW - temporoparietal fascial flap
UR - http://www.scopus.com/inward/record.url?scp=84873292988&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84873292988&partnerID=8YFLogxK
U2 - 10.1097/SCS.0b013e318270fc23
DO - 10.1097/SCS.0b013e318270fc23
M3 - Article
C2 - 23348299
AN - SCOPUS:84873292988
SN - 1049-2275
VL - 24
SP - 273
EP - 277
JO - Journal of Craniofacial Surgery
JF - Journal of Craniofacial Surgery
IS - 1
ER -