TY - JOUR
T1 - Evaluation of free-breathing three-dimensional magnetic resonance coronary angiography with hybrid ordered phase encoding (HOPE) for the detection of proximal coronary artery stenosis
AU - Bunce, Nicholas H.
AU - Jhooti, Permi
AU - Keegan, Jennifer
AU - Rahman, Shelley L.
AU - Bunce, Catherine
AU - Firmin, David N.
AU - Davies, Simon W.
AU - Lorenz, Christine H.
AU - Pennell, Dudley J.
PY - 2001
Y1 - 2001
N2 - We evaluated free-breathing, prospective navigator-gated, three-dimensional (3D) magnetic resonance coronary angiography (MRCA) with hybrid ordered phase-encoding (HOPE), in the detection of proximal coronary artery stenosis. The coronary arteries were imaged in 46 patients undergoing cardiac catheterization. The mean scan time was 48 minutes. The mean arterial length (mm) visualized was left main stem (LMS) 11.7 (SD 4.5), left anterior descending (LAD) 30.1 (SD 11.1), circumflex (LCx) 15.5 (SD 8.6), and right (RCA) 56.2 (SD 20.8). Twenty-three patients had coronary artery disease with 47 significant stenoses on cardiac catheterization. All LMS were normal on both catheterization and MRCA. MRCA sensitivity was highest for the LAD (89% CI 65%-99%) and RCA (76% CI 50%-93%), but lower for the LCx (50% CI 21%-79%). Specificity ranged from 72%-100%. Improvements in image quality, length of vessel seen, and specific imaging of the LCx are required for MRCA to become an alternative to cardiac catheterization.
AB - We evaluated free-breathing, prospective navigator-gated, three-dimensional (3D) magnetic resonance coronary angiography (MRCA) with hybrid ordered phase-encoding (HOPE), in the detection of proximal coronary artery stenosis. The coronary arteries were imaged in 46 patients undergoing cardiac catheterization. The mean scan time was 48 minutes. The mean arterial length (mm) visualized was left main stem (LMS) 11.7 (SD 4.5), left anterior descending (LAD) 30.1 (SD 11.1), circumflex (LCx) 15.5 (SD 8.6), and right (RCA) 56.2 (SD 20.8). Twenty-three patients had coronary artery disease with 47 significant stenoses on cardiac catheterization. All LMS were normal on both catheterization and MRCA. MRCA sensitivity was highest for the LAD (89% CI 65%-99%) and RCA (76% CI 50%-93%), but lower for the LCx (50% CI 21%-79%). Specificity ranged from 72%-100%. Improvements in image quality, length of vessel seen, and specific imaging of the LCx are required for MRCA to become an alternative to cardiac catheterization.
KW - Cardiac catheterization
KW - Coronary artery stenosis
KW - Hybrid ordered phase-encoding
KW - Magnetic resonance coronary angiography
KW - Prospective navigator-gated
UR - http://www.scopus.com/inward/record.url?scp=0035186298&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0035186298&partnerID=8YFLogxK
U2 - 10.1002/jmri.10013
DO - 10.1002/jmri.10013
M3 - Article
C2 - 11747023
AN - SCOPUS:0035186298
SN - 1053-1807
VL - 14
SP - 677
EP - 684
JO - Journal of Magnetic Resonance Imaging
JF - Journal of Magnetic Resonance Imaging
IS - 6
ER -